EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial

Jiajun Sun, Huiran Bai, Wei Cui, Xiaoming Wu

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024

DOI: 10.1007/s00417-023-06232-9 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Jiajun Sun und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China. Hauptthemen laut MEDLINE: Astigmatism, Lenses, Intraocular, Corneal Diseases. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To study the effect of astigmatism correction, rotational stability, and related factors of two different haptic type toric intraocular lenses. METHODS: A prospective, randomized, controlled trial. Cataract patients with preoperative corneal astigmatism of > 1 D were randomly implanted with C-loop haptic toric IOL (AcrySof-toric IOL) (group A) or plate-haptic toric IOL (AT TORBI 709 M IOL) (group B). The residual astigmatism, intraocular lens rotation, and visual quality were determined and compared between the two groups at 3 months after surgery. RESULTS: Seventy-nine eyes were included in this study, including 40 eyes in the group A and 39 eyes in the group B. No significant difference in preoperative visual acuity, intraocular pressure, and ophthalmic biological parameters was found between the two groups. There was no significant difference in residual astigmatism between the two groups at 3 months after surgery (P > 0.05). The rotation degree in the group A was 3.85 ± 2.92°, the rotation degree in the group B was 2.33 ± 2.31°, and a significant difference in intraocular lens rotation was identified between the two groups (P < 0.05). Upon exploring the rotation-related factors of the two different haptic type toric intraocular lenses, the rotation after implanting C-loop haptic toric IOL was positively correlated with axial length (Pearson r = 0.522, P = 0.01) and corneal white-to-white distance (Pearson correlation analysis r = 0.356, P = 0.024). CONCLUSIONS: The two different haptic type toric intraocular lenses effectively corrected regular corneal astigmatism and provided a good rotational stability after surgery. But the stability of plate-haptic toric IOL was better than that of C-loop haptic toric IOL. The rotational stability of C-loop haptic toric IOL was often related to axial length and corneal white-to-white distance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismLenses, IntraocularCorneal DiseasesHumansHaptic TechnologyProspective StudiesCornea

Stichwörter der Autor:innen

AstigmatismC-loop hapticCataractPlate-hapticRotational stabilityToric IOL

Autor:innen und Institutionen

  • Department of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China.
  • State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, People's Republic of…
  • Department of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China. wuxiaominglmm@126.com.

Zitieren

APA

Sun, J., Bai, H., Cui, W., & Wu, X. (2024). Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-023-06232-9

Vancouver

Sun J, Bai H, Cui W, Wu X. Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-023-06232-9

BibTeX
@article{Sun2024,
  author = {Sun, Jiajun and Bai, Huiran and Cui, Wei and Wu, Xiaoming},
  title = {Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  doi = {10.1007/s00417-023-06232-9}
}
Kostenlos starten →