Flexible and lead-free polymer composites for X-ray shielding: comparison of polyvinyl chloride matrix filled with nanoparticles of tungsten oxides
Radiation and Environmental Biophysics · 2025-03 · 64 (1) · 151-161
DOI: 10.1007/s00411-024-01103-1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiation and Environmental Biophysics, online erschienen am 10.01.2025. Verfasst von Negar Rabiei und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Yazd University, Yazd, Iran. Hauptthemen laut MEDLINE: Oxides, Tungsten, Polyvinyl Chloride, Radiation Protection. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Polymer nanocomposites have been investigated as lightweight and suitable alternatives to lead-based clothing. The present study aims to fabricate flexible, lead-free, X-ray-shielding composites using a polyvinyl chloride (PVC) matrix and different nanostructures. Four different nanostructures containing impure tungsten oxide, tungsten oxide (WO3), barium tungstate (BaWO4), and bismuth tungstate (Bi2WO6) were synthesized through various methods. Subsequently, their morphological characteristics were determined by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Also, energy-dispersive X-ray spectroscopy (EDS) analysis was performed to establish the presence of the filler in the PVC matrix. Two different weight ratios of these nanostructures (20% wt and 50% wt) were used to produce the PVC composites. To investigate attenuation parameters, the prepared composites were irradiated with X-rays at tube voltages of 40, 80, and 120 kV. The results showed that the PVC composites containing 20% wt Bi2WO6 had the highest linear attenuation coefficient (µ) at all three voltages. Furthermore, they had the lowest half-value layer (HVL), tenth-value layer (TVL), and 0.5 mm equivalent lead thickness values at each of the three voltages. The PVC composites containing 50% wt Bi2WO6 had attenuation coefficients greater than those reported for PbO at all three X-ray voltages. Among the studied tungsten nanostructures, bismuth tungstate had the best attenuation performance for X-ray protection. Additionally, this composite is light, flexible, and non-toxic, making it a promising alternative to lead aprons.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physics, Yazd University, Yazd, Iran.
- Department of Physics, Yazd University, Yazd, Iran. gholamzadeh@yazd.ac.ir.
Zitieren
APA
Rabiei, N., Gholamzadeh, L., Aminian, M. K., & Sharghi, H. (2025). Flexible and lead-free polymer composites for X-ray shielding: comparison of polyvinyl chloride matrix filled with nanoparticles of tungsten oxides. Radiation and Environmental Biophysics, 64(1), 151-161. https://doi.org/10.1007/s00411-024-01103-1
Vancouver
Rabiei N, Gholamzadeh L, Aminian MK, Sharghi H. Flexible and lead-free polymer composites for X-ray shielding: comparison of polyvinyl chloride matrix filled with nanoparticles of tungsten oxides. Radiation and Environmental Biophysics. 2025;64(1):151-161. doi:10.1007/s00411-024-01103-1
BibTeX
@article{Rabiei2025,
author = {Rabiei, Negar and Gholamzadeh, Leila and Aminian, Mohsen Khajeh and Sharghi, Hamed},
title = {Flexible and lead-free polymer composites for X-ray shielding: comparison of polyvinyl chloride matrix filled with nanoparticles of tungsten oxides},
journal = {Radiation and Environmental Biophysics},
year = {2025},
volume = {64},
number = {1},
pages = {151--161},
doi = {10.1007/s00411-024-01103-1}
}
EUVIMED