Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment
Radiation and Environmental Biophysics · 2024
DOI: 10.1007/s00411-024-01073-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation and Environmental Biophysics, 2024. Verfasst von Mahmoud Mohamed Alfishawy und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sultan Qaboos Comprehensive Cancer Care and Research Centre, Muscat, Oman. m_alfishawy@yahoo.com. Hauptthemen laut MEDLINE: Lung Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Modern radiotherapy machines offer a new modality, like flattening filter-free beam (FFF), which is used especially in stereotactic body radiation therapy (SBRT) to reduce treatment time. The remaining volume at risk (RVR) is known as undefined normal tissue, and assists in evaluating late effects such as carcinogenesis. This study aimed to compare the effects of flattening and un-flattened beams on RVR in lung cancer treated by conventional doses using volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT). Twenty-three lung cancer patients with a prescribed dose of 60 Gy delivered in 30 fractions were selected retrospectively. Four treatment plans were generated for each case (VMAT FF, VMAT FFF, IMRT FF and IMRT FFF). Mean doses to RVR and volumes that received low doses (V15Gy, V10Gy and V5Gy) were introduced as RVR evaluation parameters. Variance percentage comparison between flattening filter (FF) and FFF for the RVR evaluation parameters gave 2.38, 1.10, 1.80 and 2.22 for VMAT, and 1.73, 1.18, 1.62 and 1.81 for IMRT. In contrast, VMAT and IMRT RVR evaluation parameters resulted in variance percentage differences of 10.29, 5.02, - 8.84 and - 4.82 for FF, and 11.18, 4.96, - 8.59 and - 4.48for FFF. It is concluded that in terms of RVR evaluation parameters, FFF is clinically beneficial compared to FF for RVR, due to the decrease in mean RVR dose and low-dose irradiated RVR volume. Furthermore, VMAT is preferred in the mean RVR dose and V15Gy, while IMRT is better in V10Gy and V5Gy for RVR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sultan Qaboos Comprehensive Cancer Care and Research Centre, Muscat, Oman. m_alfishawy@yahoo.com.
- Radiation Physics, Faculty of Science, Al -Azhar University, Cairo, Egypt.
- Radiation Oncology Department, Faculty of Medicine, Al -Azhar University, Cairo, Egypt.
ORCID-Profile: Mahmoud Mohamed Alfishawy
Zitieren
APA
Alfishawy, M. M., Kany, A. I., & Elshahat, K. M. (2024). Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment. Radiation and Environmental Biophysics. https://doi.org/10.1007/s00411-024-01073-4
Vancouver
Alfishawy MM, Kany AI, Elshahat KM. Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment. Radiation and Environmental Biophysics. 2024. doi:10.1007/s00411-024-01073-4
BibTeX
@article{Alfishawy2024,
author = {Alfishawy, Mahmoud Mohamed and Kany, Amr Ismail and Elshahat, Khaled Mohamed},
title = {Impact of flattening filter-free beams on remaining volume at risk in lung cancer treatment},
journal = {Radiation and Environmental Biophysics},
year = {2024},
doi = {10.1007/s00411-024-01073-4}
}
EUVIMED