Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller
Lung · 06.11.2026 · 204 (1)
DOI: 10.1007/s00408-026-00960-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Lung, online erschienen am 06.11.2026. Verfasst von Sebastian Fernandez-Bussy und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary, Allergy, Sleep and Respiratory Medicine, Mayo Clinic, Jacksonville, FL, United States of America. fernandez-bussy.sebastian@ma…. Hauptthemen laut MEDLINE: Bronchoscopy, Lung Neoplasms, Robotic Surgical Procedures, Multiple Pulmonary Nodules. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Lung cancer screening guidelines generally recommend imaging surveillance rather than tissue sampling for nodules measuring ≤8 mm. Evidence regarding the feasibility, diagnostic performance, and safety of tissue biopsy in this lesion size remains limited. We evaluated the diagnostic performance and safety of shape-sensing robotic-assisted bronchoscopy (ssRAB) for biopsy of peripheral pulmonary nodules measuring ≤8 mm. METHODS: We conducted a retrospective single-center study of consecutive patients who underwent ssRAB between June 2020 and December 2025 for biopsy of nodules measuring ≤8 mm on pre-procedural CT imaging. The primary outcome was strict diagnostic yield, as defined by the American Thoracic Society/American College of Chest Physicians. Secondary objectives included intermediate diagnostic yield, diagnostic distribution, procedural outcomes, and complications. Diagnostic performance according to lesion size (≤ 6 mm vs. 6.1-8 mm) was evaluated separately as a subgroup analysis. RESULTS: A total of 195 nodules were included in the study. Median lesions diameter was seven mm (IQR 6-8). Strict diagnostic yield was 70.2% (137/195), while intermediate diagnostic yield was 77.4% (151/195). Malignancy was identified in 104 lesions (53.3%). The median ssRAB procedure time was 59 min (IQR 45-83). Pneumothorax occurred in six patients (3.3%), with chest tube placement required in two (1.1%). DISCUSSION: Shape-sensing robotic-assisted bronchoscopy demonstrated meaningful diagnostic performance and a favorable safety profile for peripheral pulmonary nodules measuring ≤8 mm, including lesions ≤6 mm. In this selected, higher-risk cohort, our findings suggest that earlier tissue diagnosis can be feasible and may benefit some patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary, Allergy, Sleep and Respiratory Medicine, Mayo Clinic, Jacksonville, FL, United States of America. fernandez-bussy.sebastian@mayo.edu.
- Division of Pulmonary, Allergy, Sleep and Respiratory Medicine, Mayo Clinic, Jacksonville, FL, United States of America.
- Department of Anesthesiology, Mayo Clinic, Jacksonville, FL, United States of America.
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL, United States of America.
Zitieren
APA
Fernandez-Bussy, S., Murillo-Torres, R. M., Yu Lee-Mateus, A., Rojas-Zapata, T. A., Karki, D., Evans, L., Alqawasma, M. A., Chadha, R. M., Khoor, A., Vu, L. H., Abia-Trujillo, D., & Husta, B. C. (2026). Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller. Lung, 204(1). https://doi.org/10.1007/s00408-026-00960-5
Vancouver
Fernandez-Bussy S, Murillo-Torres RM, Yu Lee-Mateus A, Rojas-Zapata TA, Karki D, Evans L, et al. Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller. Lung. 2026;204(1). doi:10.1007/s00408-026-00960-5
BibTeX
@article{FernandezBussy2026,
author = {Fernandez-Bussy, Sebastian and Murillo-Torres, Regina M and Yu Lee-Mateus, Alejandra and Rojas-Zapata, Tatiana A and Karki, Deepika and Evans, Lorna and Alqawasma, Mohammed A and Chadha, Ryan M and Khoor, Andras and Vu, Linh H and Abia-Trujillo, David and Husta, Bryan C},
title = {Diagnostic Yield and Safety Profile of Shape-Sensing Robotic-Assisted Bronchoscopy in Peripheral Pulmonary Nodules 8 mm or Smaller},
journal = {Lung},
year = {2026},
volume = {204},
number = {1},
doi = {10.1007/s00408-026-00960-5}
}
EUVIMED