EUVIMEDEUVIMED entdecken
Vergleichsstudie

Sample Adequacy PD-L1 and NGS in NSCLC: Shape-Sensing Robotic Assisted Bronchoscopy Versus CT Guided Lung Biopsy

Sebastian Fernandez-Bussy, Tatiana A Rojas-Zapata, Alejandra Yu Lee-Mateus, Regina Murillo-Torres, Lorna Evans, Andras Khoor, Ryan M Chadha, Linh H Vu, Bryan C Husta, David Abia-Trujillo

Lung · 2026

DOI: 10.1007/s00408-026-00949-0 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Lung, 2026. Verfasst von Sebastian Fernandez-Bussy und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida , 4500 San Pablo Rd, Jacksonville, FL, 32224 , USA. fernandez-bussy.sebastian…. Hauptthemen laut MEDLINE: B7-H1 Antigen, Carcinoma, Non-Small-Cell Lung, Bronchoscopy, Lung Neoplasms. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Routine assessment of programmed death-ligand 1 (PD-L1) expression and comprehensive next-generation sequencing (NGS) is recommended to guide treatment selection in patients with non-small cell lung cancer (NSCLC). Obtaining adequate tissue for biomarker and molecular analyses is therefore essential. This study compared sample adequacy for PD-L1 and NGS testing between shape-sensing robotic-assisted bronchoscopy (ssRAB) and computed tomography-guided transthoracic lung biopsy (CTTB) in patients with NSCLC.

Methods

We conducted a single-center retrospective study of patients with NSCLC who underwent biopsy of PPL by ssRAB or CTTB between June 2020 and December 2025. Demographic, procedural, pathological, biomarker and molecular data were extracted from electronic medical records, and descriptive statistics analysis and multivariable logistic regression were performed.

Results

A total of 402 patients were included, comprising 198 in the ssRAB cohort and 204 in the CTTB cohort. ssRAB demonstrated significantly higher sample adequacy rates than CTTB for both PD-L1 (98.8% vs. 90.6%, p < 0.001) and NGS testing (92.3% vs. 79.1%, p = 0.005). In multivariable logistic regression analyses, ssRAB was independently associated with higher odds of PD-L1 sample adequacy (adjusted OR 11.48, 95% CI 2.89–78.30; p = 0.002) and NGS sample adequacy (adjusted OR 4.01, 95% CI 1.64–11.40; p = 0.004) compared with CTTB. In a separate model evaluating biopsy tools, cryobiopsy use was independently associated with higher odds of PD-L1 adequacy (adjusted OR 16.54, 95% CI 2.92-317.65; p = 0.010) and NGS adequacy (adjusted OR 5.83, 95% CI 1.93–25.39; p = 0.006) compared with non-cryobiopsy sampling. Conclusions ssRAB-acquired specimens were associated with higher rates of PD-L1 and NGS sample adequacy than CTTB-acquired specimens in patients with NSCLC. Future prospective studies are needed to better understand the procedural and specimen-related factors underlying these differences.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

B7-H1 AntigenCarcinoma, Non-Small-Cell LungBronchoscopyLung NeoplasmsImage-Guided BiopsyHigh-Throughput Nucleotide SequencingRobotic Surgical ProceduresHumansFemaleMaleRetrospective StudiesTomography, X-Ray ComputedMiddle AgedAgedLung

Stichwörter der Autor:innen

CT-Guided Lung BiopsyComprehensive Next-Generation SequencingNon-small Cell Lung CancerProgrammed Death-Ligand 1Pulmonary Peripheral LesionsRobotic Bronchoscopy

Substanzen

B7-H1 AntigenCD274 protein, human

Autor:innen und Institutionen

  • Division of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida , 4500 San Pablo Rd, Jacksonville, FL, 32224 , USA. fernandez-bussy.sebastian@mayo.edu.
  • Division of Pulmonary, Allergy, and Sleep Medicine, Mayo Clinic Florida , 4500 San Pablo Rd, Jacksonville, FL, 32224 , USA.
  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL, USA.
  • Department of Anesthesiology, Mayo Clinic, Jacksonville, FL, USA.

Zitieren

APA

Fernandez-Bussy, S., Rojas-Zapata, T. A., Yu Lee-Mateus, A., Murillo-Torres, R., Evans, L., Khoor, A., Chadha, R. M., Vu, L. H., Husta, B. C., & Abia-Trujillo, D. (2026). Sample Adequacy PD-L1 and NGS in NSCLC: Shape-Sensing Robotic Assisted Bronchoscopy Versus CT Guided Lung Biopsy. Lung. https://doi.org/10.1007/s00408-026-00949-0

Vancouver

Fernandez-Bussy S, Rojas-Zapata TA, Yu Lee-Mateus A, Murillo-Torres R, Evans L, Khoor A, et al. Sample Adequacy PD-L1 and NGS in NSCLC: Shape-Sensing Robotic Assisted Bronchoscopy Versus CT Guided Lung Biopsy. Lung. 2026. doi:10.1007/s00408-026-00949-0

BibTeX
@article{FernandezBussy2026,
  author = {Fernandez-Bussy, Sebastian and Rojas-Zapata, Tatiana A and Yu Lee-Mateus, Alejandra and Murillo-Torres, Regina and Evans, Lorna and Khoor, Andras and Chadha, Ryan M and Vu, Linh H and Husta, Bryan C and Abia-Trujillo, David},
  title = {Sample Adequacy PD-L1 and NGS in NSCLC: Shape-Sensing Robotic Assisted Bronchoscopy Versus CT Guided Lung Biopsy},
  journal = {Lung},