Validation Approaches for Cough Monitoring Tools: A Scoping Review
Lung · 27.06.2026 · 204 (1)
DOI: 10.1007/s00408-026-00907-w ↗Kurz gefasst
Scoping Review in der Zeitschrift Lung, online erschienen am 27.06.2026. Verfasst von Laylaa Ramos Arriaza und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head & Neck Surgery, University of Colorado Anschutz , 12631 E. 17th Avenue, Aurora, CO, 80045, USA. Hauptthemen laut MEDLINE: Cough, Monitoring, Ambulatory. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To characterize validation approaches used in ambulatory cough monitoring systems and identify methodological variability that may limit clinical and research applications. STUDY DESIGN: Scoping review. DATA SOURCES: A comprehensive search was performed in Embase (last updated May 8, 2026), and was limited to English-language, peer-reviewed human studies. REVIEW METHODS: This review followed PRISMA-ScR guidelines. Studies were included if they reported validation of cough monitoring systems in human participants or human-derived datasets. Two reviewers independently screened and selected studies, with discrepancies resolved by a senior author. Data were extracted using a standardized form and synthesized descriptively. RESULTS: Fifty studies met inclusion criteria. Most studies evaluated adult populations (72%) and were conducted in laboratory (29%) or home (25%) settings. Validation approaches were heterogeneous, with manual human annotation used as the reference standard in 66% of studies, neural network-based approaches in 12%, and alternative methods in 22%. Definitions of cough events and outcome metrics varied widely, including counts of cough events, epochs, and time-based measures. Technologies ranged from audio-based systems to wearable sensors and machine learning-enabled platforms. While many systems demonstrated high accuracy in controlled environments, performance in real-world settings was more variable, particularly in the presence of background noise and multiple speakers. CONCLUSION: Validation of cough monitoring systems remains highly heterogeneous, with no standardized framework for reference measures or outcome metrics. Manual annotation is the most commonly used reference standard, although annotation methods and cough event definitions vary across studies. Standardization of validation protocols, development of shared datasets, and incorporation of real-world testing are needed to support clinical translation of cough monitoring technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head & Neck Surgery, University of Colorado Anschutz , 12631 E. 17th Avenue, Aurora, CO, 80045, USA.
- School of Speech, Language, Hearing, and Occupational Sciences, University of Montana, Missoula, MT, USA.
- School of Medicine, University of Colorado Anschutz , Aurora, CO, USA.
- Indivi, Basel, Switzerland.
- Department of Microbiology, Immunology and Infectious Diseases, Université de Montréal, Québec, Canada.
- Axe Immunopathologie, Centre de Recherche du Centre Hospitalier de l'Université de Montréal, Montréal, Canada.
Zitieren
APA
Ramos Arriaza, L., Slovarp, L., Abell, B. D., Galvosas, M., Grandjean Lapierre, S., & Jetté, M. E. (2026). Validation Approaches for Cough Monitoring Tools: A Scoping Review. Lung, 204(1). https://doi.org/10.1007/s00408-026-00907-w
Vancouver
Ramos Arriaza L, Slovarp L, Abell BD, Galvosas M, Grandjean Lapierre S, Jetté ME. Validation Approaches for Cough Monitoring Tools: A Scoping Review. Lung. 2026;204(1). doi:10.1007/s00408-026-00907-w
BibTeX
@article{RamosArriaza2026,
author = {Ramos Arriaza, Laylaa and Slovarp, Laurie and Abell, Brandon D and Galvosas, Mindaugas and Grandjean Lapierre, Simon and Jetté, Marie E},
title = {Validation Approaches for Cough Monitoring Tools: A Scoping Review},
journal = {Lung},
year = {2026},
volume = {204},
number = {1},
doi = {10.1007/s00408-026-00907-w}
}
EUVIMED