The Advantages of FEV1 Percent Predicted Change During Bronchial Challenge Testing
Lung · 2025
DOI: 10.1007/s00408-025-00823-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Lung, 2025. Verfasst von James Dean und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Immunology, Immunity to infection and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The U…. Hauptthemen laut MEDLINE: Bronchial Provocation Tests, Methacholine Chloride, Asthma, Bronchial Hyperreactivity. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The methacholine challenge requires a 20% fall in forced expiratory volume in one second (FEV 1 ). The fall is measured as litre (L) change from the pre-challenge (baseline) value. A higher baseline FEV 1 requires a greater volume change to reach a 20% fall. The aim of this study was to evaluate change using percent predicted, which may remove dependence on the baseline value.
Methods
Challenge data from a cohort of 114 asthma patients was re-analysed. The dose causing an 20% fall from baseline (PD 20 ) was compared to a 15% fall in predicted value (PD 15% ) for the classification of bronchial hyperresponsiveness.
Results
There was significant agreement between PD 20 and PD 15% (r = 0.95, p < 0.0001), with an ICC of 0.97. PD 20 was significantly higher than PD 15 % (0.0055 mg, p < 0.0001). Greater decreases in FEV 1 were observed with PD 20 versus PD 15% (21.4% pred vs 19.1% pred respectively, p = 0.0004), with 29% of patients requiring at least one additional dose of methacholine to achieve PD 20 compared to PD 15% . A higher baseline FEV 1 resulted in higher PD 20 values, whereas no relationship was found for PD 15% . Variability in FEV 1 between repeated visits (n = 15) was associated with the change in PD 20 , but not the change in PD 15% .
Conclusion
We suggest a PD criteria based on 15% predicted change should be used for bronchial challenge testing. This method is less influenced by baseline airflow obstruction, and is a more efficient and safer way of measuring airway hyperresponsiveness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Immunology, Immunity to infection and Respiratory Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, The University of Manchester and Manchester University NHS Foundation Trust…
- Medicines Evaluation Unit, Southmoor Road, Manchester, M23 9QZ, UK. jdean@meu.org.uk.
- Medicines Evaluation Unit, Southmoor Road, Manchester, M23 9QZ, UK.
Zitieren
APA
Dean, J., Beech, A., & Singh, D. (2025). The Advantages of FEV1 Percent Predicted Change During Bronchial Challenge Testing. Lung. https://doi.org/10.1007/s00408-025-00823-5
Vancouver
Dean J, Beech A, Singh D. The Advantages of FEV1 Percent Predicted Change During Bronchial Challenge Testing. Lung. 2025. doi:10.1007/s00408-025-00823-5
BibTeX
@article{Dean2025,
author = {Dean, James and Beech, Augusta and Singh, Dave},
title = {The Advantages of FEV1 Percent Predicted Change During Bronchial Challenge Testing},
journal = {Lung},
year = {2025},
doi = {10.1007/s00408-025-00823-5}
}