Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure

Lauren A Abplanalp, Filip Ionescu, Enrique Calvo-Ayala, Limin Yu, Girish B Nair

Lung · 2023

DOI: 10.1007/s00408-023-00625-7 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Lung, 2023. Verfasst von Lauren A Abplanalp und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care, Beaumont Health, Royal Oak, MI, USA. Hauptthemen laut MEDLINE: Airway Extubation, Respiratory Insufficiency. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Ventilator weaning protocols rely in part on objective indices to best predict extubation failure in the critically ill. We investigated static respiratory system compliance (RC) as a predictor of extubation failure, in comparison to extubation readiness using rapid shallow breathing index (RSBI). MATERIAL AND METHODS: This was a cross-sectional, multi-institutional study of mechanically ventilated patients admitted between 12/01/2017 and 12/01/2019. All patients older than 18 years with a documented spontaneous breathing trial and extubation trial were included. RC and RSBI were calculated prior to the extubation trial. The primary outcome was extubation failure-defined as need for reintubation within 72 h from time of extubation. RESULTS: Of the 2263 patients, 55.8% were males with a mean age of 68 years. The population consisted mostly of Caucasians (73%) and African Americans (20.4%). 274 (12.1%) patients required reintubation within 72 h. On multivariate logistic regression after adjusting for age, sex, body mass index (BMI), admission Sequential Organ Failure Assessment (SOFA) score, number of ventilator days, and the P/F ratio on the day of extubation, RC remained the strongest predictor for extubation failure at 24 h (aOR 1.45; 95% CI 1.00-2.10) and 72 h (aOR 1.58; 95% CI 1.15-2.17). There was no significant association between RSBI and extubation failure at 24 (aOR 1.00; 95% CI 0.99-1.01) or at 72 h (aOR 1.00; 95% CI 0.99-1.01). CONCLUSION: RC measured on the day of extubation is a promising physiological discriminant to potentially risk stratify patients with acute respiratory failure for extubation readiness. We recommend further validation studies in prospective cohorts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Airway ExtubationRespiratory InsufficiencyAgedFemaleHumansMaleCross-Sectional StudiesProspective StudiesRespiration, ArtificialRespiratory SystemVentilator Weaning

Stichwörter der Autor:innen

ExtubationMechanical ventilationRapid shallow breathing indexRespiratory FailureStatic respiratory system compliance

Autor:innen und Institutionen

  • Division of Pulmonary and Critical Care, Beaumont Health, Royal Oak, MI, USA.
  • OUWB School of Medicine, Rochester, MI, USA.
  • Moffitt Cancer Center, University of South Florida Morsani Medical School, Tampa, FL, USA.
  • Department of Pathology, Beaumont Health, Royal Oak, MI, USA.
  • Division of Pulmonary and Critical Care, Beaumont Health, Royal Oak, MI, USA. girish.nair@corewellhealth.org.
  • OUWB School of Medicine, Rochester, MI, USA. girish.nair@corewellhealth.org.

Zitieren

APA

Abplanalp, L. A., Ionescu, F., Calvo-Ayala, E., Yu, L., & Nair, G. B. (2023). Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure. Lung. https://doi.org/10.1007/s00408-023-00625-7

Vancouver

Abplanalp LA, Ionescu F, Calvo-Ayala E, Yu L, Nair GB. Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure. Lung. 2023. doi:10.1007/s00408-023-00625-7

BibTeX
@article{Abplanalp2023,
  author = {Abplanalp, Lauren A and Ionescu, Filip and Calvo-Ayala, Enrique and Yu, Limin and Nair, Girish B},
  title = {Static Respiratory System Compliance as a Predictor of Extubation Failure in Patients with Acute Respiratory Failure},
  journal = {Lung},
  year = {2023},
  doi = {10.1007/s00408-023-00625-7}
}
Kostenlos starten →