Comparative analysis of cochlear duct length using computed tomography in South Indian and Scottish populations: Implications for cochlear implant electrode selection
European Archives of Oto-Rhino-Laryngology · 08.11.2026
DOI: 10.1007/s00405-026-10761-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 08.11.2026. Verfasst von Aparajith Sathish Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of Dundee, Dundee, Scotland. 2489335@dundee.ac.uk. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Cochlear duct length (CDL) varies among individuals and populations, influencing cochlear implant (CI) electrode choice, insertion depth, and postoperative outcomes. Most CI electrode arrays are designed using Caucasian anatomical data, with limited evidence from South Asian populations. This study aimed to compare CDL between South Indian and Scottish cohorts and explore implications for population-specific CI electrode selection.
Methods
A retrospective cohort study analysed temporal bone CT scans comprising 100 cochleae from the South india cohort and 100 cochleae from the Scottish cohort. CDL was estimated using the Alexiades formula, derived from A-values measured on coronal CT images along the mid-modiolar axis. All measurements were validated independently by senior consultants to ensure accuracy and reproducibility.
Results
Mean CDL was significantly shorter in the South Indian group (26.38 ± 2.00 mm) compared with the Scottish group (33.07 ± 1.19 mm), showing an absolute difference of 6.70 mm (p < 0.001). The corresponding A-values were also smaller in the South Indian cohort (7.30 ± 0.48 mm vs. 8.91 ± 0.28 mm; p < 0.001).
Conclusion
Significant differences in estimated CDL were identified between the South Indian and Scottish cohorts. These morphometric findings demonstrate anatomical variation between the studied populations. However, their implications for cochlear implant electrode selection and clinical outcomes require prospective validation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Medicine, University of Dundee, Dundee, Scotland. 2489335@dundee.ac.uk.
- Madras ENT Research Foundation (P) Ltd, Chennai, Tamil Nadu, India.
- Royal Free London NHS Foundation Trust, London, United Kingdom.
- Department of Implantation Otology, Madras ENT Research Foundation, Chennai, Tamil Nadu, RA Puram, India.
- Department of Clinical Radiology, Ninewells Hospital and Medical School, Ninewells Avenue, Dundee, DD1 9SY, UK.
Zitieren
APA
Kumar, A. S., Vaidhyswaran, R., Lim, E., Nandhan, R., Sudarshan, T., & Kameswaran, M. (2026). Comparative analysis of cochlear duct length using computed tomography in South Indian and Scottish populations: Implications for cochlear implant electrode selection. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-026-10761-4
Vancouver
Kumar AS, Vaidhyswaran R, Lim E, Nandhan R, Sudarshan T, Kameswaran M. Comparative analysis of cochlear duct length using computed tomography in South Indian and Scottish populations: Implications for cochlear implant electrode selection. European Archives of Oto-Rhino-Laryngology. 2026. doi:10.1007/s00405-026-10761-4
BibTeX
@article{Kumar2026,
author = {Kumar, Aparajith Sathish and Vaidhyswaran, Roopak and Lim, Edward and Nandhan, Raghu and Sudarshan, Thiru and Kameswaran, Mohan},
title = {Comparative analysis of cochlear duct length using computed tomography in South Indian and Scottish populations: Implications for cochlear implant electrode selection},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2026},
doi = {10.1007/s00405-026-10761-4}
}
EUVIMED