Glass ionomer cement in incudostapedial rebridging ossiculoplasty: A systematic review and meta-analysis
European Archives of Oto-Rhino-Laryngology · 2026-10 · 283 (12) · 7587-7600
DOI: 10.1007/s00405-026-10557-6 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 31.08.2026. Verfasst von Christos Tsilivigkos und 3 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Otolaryngology, Hippokration General Hospital, National and Kapodistrian University of Athens, Athens, 15772, Greece. tsilivig@me…. Hauptthemen laut MEDLINE: Glass Ionomer Cements, Ossicular Replacement, Incus, Ear Ossicles. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the hearing outcomes and surgical success of glass ionomer cement (GIC) in incudostapedial rebridging ossiculoplasty (ISRO) in patients with different middle ear pathologies.
Methods
A systematic literature review was conducted on Medline (via PubMed), the Cochrane Database, and Scopus from database inception to July 4, 2025. Two independent authors reviewed selected studies assessing the short-, middle-, or long-term tone audiometry results, the air-bone gap (ABG) closure percentage, and cement failure outcomes. The review adhered to the PRISMA reporting standards. Meta-analysis calculated the mean differences between post- and pre-operative pure-tone audiometry values (pooled estimates and 95% confidence intervals). ABG closure was analyzed with a meta-analysis of proportions applying a logit transformation.
Results
Twenty-four studies (17 observational cohort and 8 observational case-series) were included in this review, encompassing 749 patients receiving ISRO. All studies included provided preoperative and postoperative hearing outcomes. Nineteen studies reported outcomes regarding ABG closure < 20 dB, 10 regarding closure < 10 dB, 7 regarding cement failure, and 8 regarding postoperative adverse events following ISRO. A pooled mean change in ABG values of − 16.54 dB (95% CI − 20.61 to − 12.47) and in air conduction values of − 18.01 dB (95% CI − 20.86 to − 15.17) was achieved from pre- to post-operative middle-term outcomes. The pooled success rate was 77.3% for ABG < 20 dB (95% CI 71.9–82.0), and 52.7% (95% CI 41.3–63.8) for ABG < 10 dB.
Conclusion
Incudostapedial rebridging ossiculoplasty (ISRO) appears to be a reliable solution with good hearing outcomes 1 to 3 years postoperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- First Department of Otolaryngology, Hippokration General Hospital, National and Kapodistrian University of Athens, Athens, 15772, Greece. tsilivig@med.uoa.gr.
- Department of Otolaryngology, 'Gennimatas' General Hospital, Athens, 11527, Greece.
- Department of Oral and Maxillofacial Surgery, Klinikum Dortmund, Dortmund, Germany.
- ENT Department, University Hospitals Plymouth NHS Trust, Plymouth, UK.
- Peninsula Medical School, University of Plymouth, Plymouth, UK.
Zitieren
APA
Tsilivigkos, C., Sakellaris, N., Vitkos, E. N., & Stavrakas, M. (2026). Glass ionomer cement in incudostapedial rebridging ossiculoplasty: A systematic review and meta-analysis. European Archives of Oto-Rhino-Laryngology, 283(12), 7587-7600. https://doi.org/10.1007/s00405-026-10557-6
Vancouver
Tsilivigkos C, Sakellaris N, Vitkos EN, Stavrakas M. Glass ionomer cement in incudostapedial rebridging ossiculoplasty: A systematic review and meta-analysis. European Archives of Oto-Rhino-Laryngology. 2026;283(12):7587-7600. doi:10.1007/s00405-026-10557-6
BibTeX
@article{Tsilivigkos2026,
author = {Tsilivigkos, Christos and Sakellaris, Nikolaos and Vitkos, Evangelos N and Stavrakas, Marios},
title = {Glass ionomer cement in incudostapedial rebridging ossiculoplasty: A systematic review and meta-analysis},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2026},
volume = {283},
number = {12},
pages = {7587--7600},
doi = {10.1007/s00405-026-10557-6}
}
EUVIMED