EUVIMEDEUVIMED entdecken
Crossref

Evaluation of sigmoid sinus hemodynamics through four-dimensional flow magnetic resonance imaging in pulsatile tinnitus patients caused by sigmoid sinus wall dehiscence coexisting with idiopathic intracranial hypertension

Lanyue Chen, Ruirong Chen, Xiancong Liu, Xiaobo Ma, Rui Li, Haining Wei, Zhaohui Liu

European Archives of Oto-Rhino-Laryngology · 2026

DOI: 10.1007/s00405-026-10321-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2026. Verfasst von Lanyue Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No.1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, …. Hauptthemen laut MEDLINE: Tinnitus, Cranial Sinuses, Magnetic Resonance Imaging, Hemodynamics. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate hemodynamics in the sigmoid sinus of sigmoid sinus wall dehiscence (SSWD)-pulsatile tinnitus (PT) patients with idiopathic intracranial hypertension using four-dimensional (4D) flow MRI. METHODS: Thirty-five SSWD-PT patients with idiopathic intracranial hypertension were prospectively enrolled, together with 35 age-, sex-matched healthy controls and underwent MRI. Hemodynamics in the sigmoid sinus were evaluated by 4D flow MRI. Receiver operating characteristic curves and logistic regression analysis evaluated the ability of the hemodynamic indicators to differentiate SSWD-PT patients from healthy controls. RESULTS: PT patients presented significantly increased maximum velocity [86.77 ± 7.92 cm/s vs. 46.32 (38.89, 53.96) cm/s], maximum through-plane velocity (Vtp_max) (63.83 ± 16.89 cm/s vs. 45.65 ± 10.92 cm/s), backward flow volume [0.27 (0.06, 0.84) mL vs. 0.04 (0.01, 0.06) mL], regurgitant fraction [10.73 (2.11, 24.30) % vs. 0.47 (0.17, 1.31) %], and average wall shear stress (WSSavg) [0.27 (0.24, 0.33) N/m2 vs. 0.14 (0.11, 0.19) N/m2] (all p < 0.001). Average velocity (18.47 ± 2.69 cm/s vs. 21.97 ± 6.66 cm/s), average through-plane velocity [5.06 (3.25, 7.74) cm/s vs. 20.30 ± 6.44 cm/s], forward flow volume [3.70 (2.40, 5.44) mL vs. 6.90 ± 3.50 mL], and average blood flow (4.16 ± 2.03 mL/s vs. 7.42 ± 3.67 mL/s) were significantly decreased in PT group (all p < 0.05). Abnormal vortex or turbulent flow occurred in 88.6% of patients, none in controls (p < 0.001). The combination of Vtp_max and WSSavg showed the highest ability to differentiate SSWD-PT patients from healthy controls (AUC = 0.956). CONCLUSION: SSWD-PT patients have hemodynamic changes in the sigmoid sinus. The combination of Vtp_max and WSSavg may serve as a valuable noninvasive indicator for differentiating SSWD-PT patients from healthy controls.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TinnitusCranial SinusesMagnetic Resonance ImagingHemodynamicsPseudotumor CerebriHumansFemaleMaleAdultMiddle AgedProspective StudiesBlood Flow VelocityROC CurveCase-Control Studies

Stichwörter der Autor:innen

Four-dimensional flow MRIHemodynamicsIdiopathic intracranial hypertensionPulsatile tinnitusSigmoid sinus wall dehiscence

Autor:innen und Institutionen

  • Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No.1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, China.
  • Department of Anesthesiology, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Department of Otolaryngology Head and Neck surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China.
  • Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No.1 Dong Jiao Min Xiang Street, Dongcheng District, Beijing, 100730, China. lzhtrhos@163.com.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Chen, L., Chen, R., Liu, X., Ma, X., Li, R., Wei, H., & Liu, Z. (2026). Evaluation of sigmoid sinus hemodynamics through four-dimensional flow magnetic resonance imaging in pulsatile tinnitus patients caused by sigmoid sinus wall dehiscence coexisting with idiopathic intracranial hypertension. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-026-10321-w

Vancouver

Chen L, Chen R, Liu X, Ma X, Li R, Wei H, et al. Evaluation of sigmoid sinus hemodynamics through four-dimensional flow magnetic resonance imaging in pulsatile tinnitus patients caused by sigmoid sinus wall dehiscence coexisting with idiopathic intracranial hypertension. European Archives of Oto-Rhino-Laryngology. 2026. doi:10.1007/s00405-026-10321-w

BibTeX
@article{Chen2026,
  author = {Chen, Lanyue and Chen, Ruirong and Liu, Xiancong and Ma, Xiaobo and Li, Rui and Wei, Haining and Liu, Zhaohui},
  title = {Evaluation of sigmoid sinus hemodynamics through four-dimensional flow magnetic resonance imaging in pulsatile tinnitus patients caused by sigmoid sinus wall dehiscence coexisting with idiopathic intracranial hypertension},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2026},
  doi = {10.1007/s00405-026-10321-w}
}
Kostenlos starten →