EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A novel technique for safe intraoperative perilymph sampling in humans

William Shute, Dongcheng Zhang, Amy Hampson, Jean-Marc Gerard, Stephen J O'Leary

European Archives of Oto-Rhino-Laryngology · 2026-08 · 283 (8) · 5007-5018

DOI: 10.1007/s00405-026-10256-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 10.06.2026. Verfasst von William Shute und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, The University of Melbourne, 32 Gisborne St, East Melbourne, 3002, Australia. wshute@student.unimelb.edu.au. Hauptthemen laut MEDLINE: Perilymph, Cochlear Implantation, Catheters. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Melbourne.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To calibrate nylon epidural catheters against glass capillaries for obtaining reliable volume yields and present the development and implementation of a translatable human perilymph sampling methodology which minimally impacts cochlear function.

Methods

Two gauges of nylon epidural catheters were calibrated against glass capillary tubes to establish the minimum fluid column height to yield a desired sample volume. We also report development of a proposed surgical methodology for in vivo sampling, and implementation in a clinical cohort study of cochlear implant recipients. We assessed the impact of sampling on hearing in a subset of hearing preservation candidates.

Results

Correlation equations for both 18G and 16G catheters yielding a desired sample volume ‘x’ with a fluid column height ‘y’. The equations for 18G and 16G catheters respectively are y = 6.538x + 1.0894 and 3.8008x + 0.6754. A sampling apparatus consisting of an epidural catheter passed through a house suction tip attached to a 1 mL syringe provides optimal ergonomics and manoeuvrability. Extracochlear ECochG amplitudes and thresholds are unaffected by collection of perilymph using this technique, as were 3-month hearing preservation outcomes.

Conclusion

These results describe a safe, accurate and transferrable alternative to using glass capillaries to sample directly from the human inner ear during surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PerilymphCochlear ImplantationCathetersHumansFemaleMaleAdultCalibrationCochlear ImplantsMiddle AgedChild

Stichwörter der Autor:innen

Cochlear implantationElectrocochleographyHearing lossHuman researchPerilymph sampling

Autor:innen und Institutionen

  • Department of Otolaryngology, The University of Melbourne, 32 Gisborne St, East Melbourne, 3002, Australia. wshute@student.unimelb.edu.au.
  • Department of Otolaryngology, The University of Melbourne, 32 Gisborne St, East Melbourne, 3002, Australia.

Förderung

  • University of Melbourne

Zitieren

APA

Shute, W., Zhang, D., Hampson, A., Gerard, J. M., & O'Leary, S. J. (2026). A novel technique for safe intraoperative perilymph sampling in humans. European Archives of Oto-Rhino-Laryngology, 283(8), 5007-5018. https://doi.org/10.1007/s00405-026-10256-2

Vancouver

Shute W, Zhang D, Hampson A, Gerard JM, O'Leary SJ. A novel technique for safe intraoperative perilymph sampling in humans. European Archives of Oto-Rhino-Laryngology. 2026;283(8):5007-5018. doi:10.1007/s00405-026-10256-2

BibTeX
@article{Shute2026,
  author = {Shute, William and Zhang, Dongcheng and Hampson, Amy and Gerard, Jean-Marc and O'Leary, Stephen J},
  title = {A novel technique for safe intraoperative perilymph sampling in humans},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2026},
  volume = {283},
  number = {8},
  pages = {5007--5018},
  doi = {10.1007/s00405-026-10256-2}
}
Kostenlos starten →