Volume rendering technique and high-resolution microCT: 3D exploration of the cochlear anatomy
European Archives of Oto-Rhino-Laryngology · 2025-09 · 282 (9) · 4497-4504
DOI: 10.1007/s00405-025-09360-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 03.04.2025. Verfasst von Gabriela O'Toole Bom Braga und 3 weiteren Autor:innen. Beteiligte Einrichtung: Artorg Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Cochlea, Imaging, Three-Dimensional, X-Ray Microtomography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bern.
Abstract (Originalsprache)
Purpose
Given its unique anatomical position and the amalgamation of bony and soft tissues within the cochlea, exploring its intricacies poses persistent challenges. Histopathology remains the gold standard in research, but given its inherent limitations, there is a clear need for innovative alternatives. The integration of microCT technology with advanced volume rendering techniques emerges as a promising approach for overcoming the hurdles associated with anatomical investigations of the cochlea.
Methods
We seamlessly integrated high-resolution microCT cochlear images with medical imaging analysis software to create detailed 3D anatomical images of the human cochlea without the need of sample processing.
Results
Volume rendering allowed a multiplanar, non-destructive, detailed anatomical evaluation of the human cochlea, including its capillary system, as well as soft tissue visualization at single-micron resolution in 3D.
Conclusion
The use of volume rendering in cochlear anatomical studies is underexplored despite the prevalence of 3D reconstruction. This technique presents a promising avenue for scientific investigation, providing researchers with unprecedented insights that can potentially benefit patients with hearing disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Artorg Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
- Center for X- Ray Analytics, Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland.
- Department of Diagnostic and Interventional Neuroradiology Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, University of Bern, 3010, Bern, Switzerland. franca.wagner@ins…
- Department of Otorhinolaryngology - Head and Neck Surgery, Inselspital, University Hospital University of Bern, University of Bern, Bern, Switzerland. franca.wagner@insel.ch.
Förderung
- University of Bern
Zitieren
APA
Braga, G. O. B., Zboray, R., Parrilli, A., & Wagner, F. (2025). Volume rendering technique and high-resolution microCT: 3D exploration of the cochlear anatomy. European Archives of Oto-Rhino-Laryngology, 282(9), 4497-4504. https://doi.org/10.1007/s00405-025-09360-6
Vancouver
Braga GOB, Zboray R, Parrilli A, Wagner F. Volume rendering technique and high-resolution microCT: 3D exploration of the cochlear anatomy. European Archives of Oto-Rhino-Laryngology. 2025;282(9):4497-4504. doi:10.1007/s00405-025-09360-6
BibTeX
@article{Braga2025,
author = {Braga, Gabriela O'Toole Bom and Zboray, Robert and Parrilli, Annapaola and Wagner, Franca},
title = {Volume rendering technique and high-resolution microCT: 3D exploration of the cochlear anatomy},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2025},
volume = {282},
number = {9},
pages = {4497--4504},
doi = {10.1007/s00405-025-09360-6}
}