Participant valued appearance of bone conduction devices: a comparison between percutaneous and transcutaneous systems
European Archives of Oto-Rhino-Laryngology · 2025
DOI: 10.1007/s00405-025-09335-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2025. Verfasst von Hidde K Krijnen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, PO Box 30.001, Groningen, 9700 RB, The Netherlands. h.k…. Hauptthemen laut MEDLINE: Bone Conduction, Hearing Aids, Hearing Loss, Conductive, Patient Preference. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To investigate whether the appearance of percutaneous bone conduction devices (perBCDs) or active transcutaneous bone conduction devices (atBCDs) is preferred by BCD-users and non-users. The second aim is to examine the degree to which the appearance of a device matters in comparison to other BCD traits, and whether certain participant characteristics predict this.
Methods
An online questionnaire was designed and administered to BCD-users and non-users (i.e., persons with no experience using a BCD). Pair-wise comparisons showing pictures of the latest generation perBCD and atBCD sound processors and implant sites were anonymously provided to participants, who could indicate their preference. Sum scores were calculated ranging from − 2 (strong preference for perBCD) to 2 (strong preference for atBCD). Means for the total score as well as sub scores of pictures showing either sound processor or implant site were calculated. Statements were presented in which the appearance of the device was weighed against other traits such as better hearing.
Results
The study population consisted of 102 BCD-users and 105 non-users. An overall preference for perBCD sound processors was observed (mean score − 0.50 (95% CI: -0.63, -0.37). BCD-users had no preference for implant sites whilst non-users preferred atBCDs (-0.03 (-0.27, 0.21) and 0.60 (0.40, 0.80) respectively, p < 0.01). Most participants found better hearing more important than having an appealing device ( n = 150, 73.0%).
Conclusions
PerBCD sound processors were preferred over atBCD sound processors by both BCD-users and non-users. Functionality seems to be more important than the appearance of the device.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, PO Box 30.001, Groningen, 9700 RB, The Netherlands. h.k.krijnen@umcg.nl.
- Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, PO Box 30.001, Groningen, 9700 RB, The Netherlands.
- Research School of Behavioral and Cognitive Neurosciences, Graduate School of Medical Sciences, University of Groningen, Groningen, The Netherlands.
- Department of Otorhinolaryngology/Head and Neck Surgery, Radboud University Medical Center, Nijmegen, The Netherlands.
Zitieren
APA
Krijnen, H. K., Aukema, T. W., & Hol, M. K. S. (2025). Participant valued appearance of bone conduction devices: a comparison between percutaneous and transcutaneous systems. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-025-09335-7
Vancouver
Krijnen HK, Aukema TW, Hol MKS. Participant valued appearance of bone conduction devices: a comparison between percutaneous and transcutaneous systems. European Archives of Oto-Rhino-Laryngology. 2025. doi:10.1007/s00405-025-09335-7
BibTeX
@article{Krijnen2025,
author = {Krijnen, Hidde K and Aukema, Tjerk W and Hol, Myrthe K S},
title = {Participant valued appearance of bone conduction devices: a comparison between percutaneous and transcutaneous systems},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2025},
doi = {10.1007/s00405-025-09335-7}
}
EUVIMED