Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness

Anja Kurz, David Herrmann, Franz-Tassilo Müller-Graff, Johannes Voelker, Stephan Hackenberg, Kristen Rak

European Archives of Oto-Rhino-Laryngology · 2025-01 · 282 (1) · 467-479

DOI: 10.1007/s00405-024-08984-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 19.09.2024. Verfasst von Anja Kurz und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Comprehensive Hearing Center, University Hospital Würzburg, Josef-Schneider-Str. 11, 9708…. Hauptthemen laut MEDLINE: Speech Perception, Cochlear Implants, Hearing Loss, Unilateral, Cochlear Implantation. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Würzburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate objective and subjective hearing outcomes in experienced cochlear implant users with single sided deafness (SSD CI) who used fitting maps created via anatomy-based fitting (ABF) and clinically-based fitting (CBF).

Participants

Twelve SSD CI users with postlingual hearing loss.

Intervention

OTOPLAN (Version 3. (MED-EL) was used to determine intracochlear electrode contact positions using post-operative high-resolution flat panel volume computed tomography. From these positions, the corresponding center frequencies and bandwidths were derived for each channel. These were implemented in the clinical fitting software MAESTRO to yield an ABF map individualized to each user. Main Outcome Measures ABF and CBF maps were compared. Objective speech perception in quiet and in noise, binaural effects, and self-perceived sound quality were evaluated.

Results

Significantly higher speech perception in noise scores were observed with the ABF map compared to the CBF map (mean SRT 50 : -6.49 vs. -4.8 dB SNR for the S 0 N CI configuration and − 3.85 vs. -2.75 dB SNR for the S 0 N 0 configuration). Summation and squelch effects were significantly increased with the ABF map (0.86 vs. 0.21 dB SNR for summation and 0.85 vs. -0.09 dB SNR for squelch). No improvement in speech perception in quiet or spatial release from masking were observed with the ABF map. A similar level of self-perceived sound quality was reported for each map. Upon the end of the study, all users opted to keep the ABF map. This preference was independent of the angular insertion depth of the electrode array.

Conclusions

Experienced SSD CI users preferred using the ABF map, which gave them significant improvements in binaural hearing and some aspects of speech perception.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Speech PerceptionCochlear ImplantsHearing Loss, UnilateralCochlear ImplantationProsthesis FittingHumansMaleFemaleMiddle AgedNoiseAdultAgedTomography, X-Ray Computed

Stichwörter der Autor:innen

Anatomy-based fittingCochlear implant in single sided deafnessFrequency-to-place mismatchSpeech perception

Autor:innen und Institutionen

  • Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Comprehensive Hearing Center, University Hospital Würzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany. Kurz_A@ukw.de.
  • Department of Oto-Rhino-Laryngology, Head and Neck Surgery, Comprehensive Hearing Center, University Hospital Würzburg, Josef-Schneider-Str. 11, 97080, Würzburg, Germany.

Förderung

  • Universitätsklinikum Würzburg

Zitieren

APA

Kurz, A., Herrmann, D., Müller-Graff, F. T., Voelker, J., Hackenberg, S., & Rak, K. (2025). Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness. European Archives of Oto-Rhino-Laryngology, 282(1), 467-479. https://doi.org/10.1007/s00405-024-08984-4

Vancouver

Kurz A, Herrmann D, Müller-Graff FT, Voelker J, Hackenberg S, Rak K. Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness. European Archives of Oto-Rhino-Laryngology. 2025;282(1):467-479. doi:10.1007/s00405-024-08984-4

BibTeX
@article{Kurz2025,
  author = {Kurz, Anja and Herrmann, David and Müller-Graff, Franz-Tassilo and Voelker, Johannes and Hackenberg, Stephan and Rak, Kristen},
  title = {Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2025},
  volume = {282},
  number = {1},
  pages = {467--479},
  doi = {10.1007/s00405-024-08984-4}
}
Kostenlos starten →