The digital scent device 20: an automated, self-administered odor identification test
European Archives of Oto-Rhino-Laryngology · 2024
DOI: 10.1007/s00405-024-08887-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, 2024. Verfasst von Agnieszka Sabiniewicz und 6 weiteren Autor:innen. Beteiligte Einrichtung: Smell and Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany. a.sabiniewicz@gmail.com. Hauptthemen laut MEDLINE: Odorants, Olfaction Disorders, COVID-19. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technische Universität Dresden.
Abstract (Originalsprache)
Purpose
Assessing olfactory function is highly significant in clinical practice, particularly in the context of the recent COVID-19 pandemic. Recent approaches in this field emphasize the importance of reducing the time and cost devoted to olfactory testing procedures. Hence, the aim of the present study was to examine the reliability and basic characteristics of Digital Scent Device 20 (DSD-20), an innovative olfactory test consisting of 20 “universal odors”, in a European population.
Methods
A total of 88 participants (mean age = 45.1, SD = 20.3) volunteered for the study. The sample consisted of 37 normosmic controls and 51 dysosmic patients.
Results
The correlation between DSD-20 and the total score in Sniffin’ Sticks was high (TDI; R = .80, p < .001), and the test correlated with the individual components of the Sniffin’ Sticks test. Furthermore, the correlation coefficient between DSD-20 test and retest was very high ( R = .88, p < .001), which was additionally confirmed by a Bland-Altman plot. Essential characteristics of the DSD-20 are its simplicity in self-administration, speed of application, portability, and the fact that it can be reused.
Conclusion
Overall, the present study confirms previous notions on DSD-20 by demonstrating its high reliability and usefulness in separating patients with hyposmia/anosmia and normosmic controls.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Smell and Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany. a.sabiniewicz@gmail.com.
- Smell and Taste Clinic, Department of Otorhinolaryngology, TU Dresden, Dresden, Germany.
- NOAR, Sao Paulo, Brazil.
- Department of Otorhinolaryngology, University Hospital of Brasília UnB-EBSERH, University of Brasilia, Brasilia, Federal District, Brazil.
Förderung
- Technische Universität Dresden
Zitieren
APA
Sabiniewicz, A., Wittig, S., Haehner, A., Müller, C., Galvao, C., Nakanishi, M., & Hummel, T. (2024). The digital scent device 20: an automated, self-administered odor identification test. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-024-08887-4
Vancouver
Sabiniewicz A, Wittig S, Haehner A, Müller C, Galvao C, Nakanishi M, et al. The digital scent device 20: an automated, self-administered odor identification test. European Archives of Oto-Rhino-Laryngology. 2024. doi:10.1007/s00405-024-08887-4
BibTeX
@article{Sabiniewicz2024,
author = {Sabiniewicz, Agnieszka and Wittig, Sophia and Haehner, Antje and Müller, Christopher and Galvao, Claudia and Nakanishi, Marco and Hummel, Thomas},
title = {The digital scent device 20: an automated, self-administered odor identification test},
journal = {European Archives of Oto-Rhino-Laryngology},
year = {2024},
doi = {10.1007/s00405-024-08887-4}
}
EUVIMED