EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Volumetry improves the assessment of the vestibular aqueduct size in inner ear malformation

Nora M Weiss, Tabita M Breitsprecher, Alexander Pscheidl, David Bächinger, Stefan Volkenstein, Stefan Dazert, Robert Mlynski, Sönke Langner, Peter Roland, Anandhan Dhanasingh

European Archives of Oto-Rhino-Laryngology · 2023-05 · 280 (5) · 2155-2163

DOI: 10.1007/s00405-022-07681-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Archives of Oto-Rhino-Laryngology, online erschienen am 10.10.2022. Verfasst von Nora M Weiss und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany. nora.weiss@rub.de. Hauptthemen laut MEDLINE: Hearing Loss, Sensorineural, Vestibular Aqueduct. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ruhr-Universität Bochum.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Enlarged vestibular aqueduct (EVA) is a common finding associated with inner ear malformations (IEM). However, uniform radiologic definitions for EVA are missing and various 2D-measurement methods to define EVA have been reported. This study evaluates VA volume in different types of IEM and compares 3D-reconstructed VA volume to 2D-measurements.

Methods

A total of 98 high-resolution CT (HRCT) data sets from temporal bones were analyzed (56 with IEM; [cochlear hypoplasia (CH; n = 18), incomplete partition type I (IPI; n = 12) and type II (IPII; n = 11) and EVA ( n = 15)]; 42 controls). VA diameter was measured in axial images. VA volume was analyzed by software-based, semi-automatic segmentation and 3D-reconstruction. Differences in VA volume between the groups and associations between VA volume and VA diameter were assessed. Inter-rater-reliability (IRR) was assessed using the intra-class-correlation-coefficient (ICC).

Results

Larger VA volumes were found in IEM compared to controls. Significant differences in VA volume between patients with EVA and controls ( p < 0.001) as well as between IPII and controls ( p < 0.001) were found. VA diameter at the midpoint (VA midpoint) and at the operculum (VA operculum) correlated to VA volume in IPI (VA midpoint: r = 0.78, VA operculum: r = 0.91), in CH (VA midpoint: r = 0.59, VA operculum: r = 0.61), in EVA (VA midpoint: r = 0.55, VA operculum: r = 0.66) and in controls (VA midpoint: r = 0.36, VA operculum: r = 0.42). The highest IRR was found for VA volume (ICC = 0.90).

Conclusions

The VA diameter may be an insufficient estimate of VA volume, since (1) measurement of VA diameter does not reliably correlate with VA volume and (2) VA diameter shows a lower IRR than VA volume. 3D-reconstruction and VA volumetry may add information in diagnosing EVA in cases with or without additional IEM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hearing Loss, SensorineuralVestibular AqueductHumansReproducibility of ResultsRetrospective StudiesCochlea

Stichwörter der Autor:innen

3D segmentationCochlear malformationDiagnosisInner ear malformationVolume

Autor:innen und Institutionen

  • Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany. nora.weiss@rub.de.
  • Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium. nora.weiss@rub.de.
  • Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany.
  • Department of Otorhinolaryngology, Head and Neck Surgery, Medical Center, Dortmund, Germany.
  • Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, Zurich, Switzerland.
  • University of Zurich, Zurich, Switzerland.

Förderung

  • Ruhr-Universität Bochum

Zitieren

APA

Weiss, N. M., Breitsprecher, T. M., Pscheidl, A., Bächinger, D., Volkenstein, S., Dazert, S., Mlynski, R., Langner, S., Roland, P., & Dhanasingh, A. (2023). Volumetry improves the assessment of the vestibular aqueduct size in inner ear malformation. European Archives of Oto-Rhino-Laryngology, 280(5), 2155-2163. https://doi.org/10.1007/s00405-022-07681-4

Vancouver

Weiss NM, Breitsprecher TM, Pscheidl A, Bächinger D, Volkenstein S, Dazert S, et al. Volumetry improves the assessment of the vestibular aqueduct size in inner ear malformation. European Archives of Oto-Rhino-Laryngology. 2023;280(5):2155-2163. doi:10.1007/s00405-022-07681-4

BibTeX
@article{Weiss2023,
  author = {Weiss, Nora M and Breitsprecher, Tabita M and Pscheidl, Alexander and Bächinger, David and Volkenstein, Stefan and Dazert, Stefan and Mlynski, Robert and Langner, Sönke and Roland, Peter and Dhanasingh, Anandhan},
  title = {Volumetry improves the assessment of the vestibular aqueduct size in inner ear malformation},
  journal = {European Archives of Oto-Rhino-Laryngology},
  year = {2023},
  volume = {280},
  number = {5},
  pages = {2155--2163},
  doi = {10.1007/s00405-022-07681-4}
}
Kostenlos starten →