EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY-NC-ND 4.0

Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study

Yuxuan Ding, Yuan Wang, Yutian Chen, Mo Liu, Chenyan Dai, Lan Yang, Yan Xu

Archives of Gynecology and Obstetrics · 07.09.2026

DOI: 10.1007/s00404-026-08520-1 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Archives of Gynecology and Obstetrics, online erschienen am 07.09.2026. Verfasst von Yuxuan Ding und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Nanjing Drum Tower Hospital Clinical Research Special Fund project, New Technology Development Project of Nanjing Drum Tower Hospital.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The etiology of preterm birth is complex and multifaceted, involving factors such as preterm cervical softening and remodeling, which poses challenges for prediction. Ultrasound, as a convenient and non-invasive tool, is commonly used to assess the cervix during pregnancy. However, cervical length measurement has limited accuracy in predicting preterm birth, highlighting the urgent need for more specific indicators to evaluate the cervix during gestation.

Objectives

This study aimed to investigate regional differences in cervical viscoelastic parameters, evaluate their changes between the first and second trimesters using paired statistical tests, and explore their association with cervical length via ultrasound viscoelastic imaging, thereby providing a foundation for future research on preterm birth prediction. Study Design A prospective cohort trial enrolled pregnant women undergoing prenatal examinations at Nanjing Drum Tower Hospital from May 2024 to October 2025. Viscoelastic parameters (shear elastic modulus, viscosity coefficient, and dispersion coefficient) were measured at the internal, middle, and external segments of both the anterior and posterior cervical lips by a Mindray Resona R9 ultrasound system equipped with a 7–9 MHz transvaginal probe at 11–13⁺⁶ weeks and 22–24⁺⁶ weeks of gestation. Viscoelasticity is an indicator for evaluating the intrinsic properties of tissue; higher values indicate stiffer and more viscous tissue.

Results

From the first to the second trimester, the mean of all viscoelastic measurements of the anterior and posterior cervical lips decreased significantly ( P 0.75).

Conclusions

Our study establishes reference ranges for cervical viscoelastic parameters in the first and second trimesters thereby providing new quantitative tools and reference data for assessing the cervix during pregnancy. Their clinical value is yet to be determined.

Förderung

  • Nanjing Drum Tower Hospital Clinical Research Special Fund project
  • New Technology Development Project of Nanjing Drum Tower Hospital

Zitieren

APA

Ding, Y., Wang, Y., Chen, Y., Liu, M., Dai, C., Yang, L., & Xu, Y. (2026). Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study. Archives of Gynecology and Obstetrics. https://doi.org/10.1007/s00404-026-08520-1

Vancouver

Ding Y, Wang Y, Chen Y, Liu M, Dai C, Yang L, et al. Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study. Archives of Gynecology and Obstetrics. 2026. doi:10.1007/s00404-026-08520-1

BibTeX
@article{Ding2026,
  author = {Ding, Yuxuan and Wang, Yuan and Chen, Yutian and Liu, Mo and Dai, Chenyan and Yang, Lan and Xu, Yan},
  title = {Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study},
  journal = {Archives of Gynecology and Obstetrics},
  year = {2026},
  doi = {10.1007/s00404-026-08520-1}
}
Kostenlos starten →