EUVIMEDEUVIMED entdecken
VergleichsstudieRandomisierte kontrollierte StudieValidierungsstudieOpen Access · CC BY 4.0

Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model

Anne Cathrine Scherer-Quenzer iD, Katharina Reinhart, Joachim Diessner, Anastasia Altides, Johanna Buechel, Bettina Blau-Schneider, Stephanie Tina Sauer, Barbara Deschler-Baier, Achim Woeckel, Matthias Kiesel iD

Archives of Gynecology and Obstetrics · 04.04.2026 · 313 (1)

DOI: 10.1007/s00404-026-08413-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Gynecology and Obstetrics, online erschienen am 04.04.2026. Verfasst von Anne Cathrine Scherer-Quenzer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany. quenzer_a@ukw.de. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Simulation Training, Gynecologic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Würzburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Traditional surgical training methods such as "learning-by-doing" raise ethical and methodological concerns. To improve training and reduce patient risk, a 3D-printed LLETZ simulator was developed. While initial studies showed advantages over a conventional model, they were limited to medical students and lacked comparison with a commercially available simulator.

Methods

A single-center study was conducted at the University Hospital Wuerzburg. 60 medical students without prior LLETZ experience and 10 gynecology residents with prior exposure were randomly assigned to train on either a commercial or the novel in-house simulator. Each participant performed five electrosurgical excisions. Performance was evaluated using LEEP scores, resection status (R0 resections), and blinded video assessments by two senior clinicians. Additionally, participants completed questionnaires, to capture subjective training impressions.

Results

The in-house simulator demonstrated superior performance compared to the commercial model. When analyzed separately, changes in LEEP scores over the five attempts were statistically significant for both simulators. The effect size was larger for the in-house simulator ( η 2 = 0.227) than for the conventional simulator ( η 2 = 0.10). Within-group analysis revealed no significant pairwise differences across all attempts for the commercial simulator. In contrast, several pairwise comparisons remained statistically significant for the in-house simulator (attempts 1 vs. 3, 1 vs. 4, 2 vs. 5, and 1 vs. 5), all with large effect sizes (Cohen’s d > 1.1). Between-group comparison of individual LEEP scores showed a statistically significant difference in the fifth attempt ( p = 0.002), with a large effect size (Cohen’s d = 1.01) favoring the in-house simulator. Higher R0 resection rates were observed with the in-house simulator in the third (100% vs. 83.3%) and fourth attempts (96.7% vs. 73.3%). Blinded video assessments by two senior experts confirmed these findings, demonstrating higher checklist, Global Rating Scale (GRS), and overall mean scores for the in-house simulator from the third attempt onward (all p < 0.05; all Cohen’s d > 0.8). Participant feedback further supported these results, indicating improved confidence, technical skills, and perceived educational value.

Conclusion

This study demonstrated that the novel in-house 3D-printed simulator significantly outperformed the commercial model in objective surgical performance, learning progression and user satisfaction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalSimulation TrainingGynecologic Surgical ProceduresHumansFemaleCost-Benefit AnalysisClinical CompetenceInternship and ResidencyGynecology

Stichwörter der Autor:innen

3D printingLEEP scoreLLETZ simulationSimulation trainingSurgical trainingVideo evaluation

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany. quenzer_a@ukw.de.
  • Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany.
  • Department of Radiology, University Hospital Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
  • Translational Oncology, Comprehensive Cancer Center Mainfranken, University Hospital Wuerzburg, Josef-Schneider-Str. 6, 97080, Würzburg, Germany.

ORCID-Profile: Anne Cathrine Scherer-Quenzer, Matthias Kiesel

Förderung

  • Universitätsklinikum Würzburg

Zitieren

APA

Scherer-Quenzer, A. C., Reinhart, K., Diessner, J., Altides, A., Buechel, J., Blau-Schneider, B., Sauer, S. T., Deschler-Baier, B., Woeckel, A., & Kiesel, M. (2026). Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model. Archives of Gynecology and Obstetrics, 313(1). https://doi.org/10.1007/s00404-026-08413-3

Vancouver

Scherer-Quenzer AC, Reinhart K, Diessner J, Altides A, Buechel J, Blau-Schneider B, et al. Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model. Archives of Gynecology and Obstetrics. 2026;313(1). doi:10.1007/s00404-026-08413-3

BibTeX
@article{SchererQuenzer2026,
  author = {Scherer-Quenzer, Anne Cathrine and Reinhart, Katharina and Diessner, Joachim and Altides, Anastasia and Buechel, Johanna and Blau-Schneider, Bettina and Sauer, Stephanie Tina and Deschler-Baier, Barbara and Woeckel, Achim and Kiesel, Matthias},
  title = {Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model},
  journal = {Archives of Gynecology and Obstetrics},
  year = {2026},
  volume = {313},
  number = {1},
  doi = {10.1007/s00404-026-08413-3}
}
Kostenlos starten →