Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model
Archives of Gynecology and Obstetrics · 04.04.2026 · 313 (1)
DOI: 10.1007/s00404-026-08413-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Gynecology and Obstetrics, online erschienen am 04.04.2026. Verfasst von Anne Cathrine Scherer-Quenzer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany. quenzer_a@ukw.de. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Simulation Training, Gynecologic Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Würzburg.
Abstract (Originalsprache)
Purpose
Traditional surgical training methods such as "learning-by-doing" raise ethical and methodological concerns. To improve training and reduce patient risk, a 3D-printed LLETZ simulator was developed. While initial studies showed advantages over a conventional model, they were limited to medical students and lacked comparison with a commercially available simulator.
Methods
A single-center study was conducted at the University Hospital Wuerzburg. 60 medical students without prior LLETZ experience and 10 gynecology residents with prior exposure were randomly assigned to train on either a commercial or the novel in-house simulator. Each participant performed five electrosurgical excisions. Performance was evaluated using LEEP scores, resection status (R0 resections), and blinded video assessments by two senior clinicians. Additionally, participants completed questionnaires, to capture subjective training impressions.
Results
The in-house simulator demonstrated superior performance compared to the commercial model. When analyzed separately, changes in LEEP scores over the five attempts were statistically significant for both simulators. The effect size was larger for the in-house simulator ( η 2 = 0.227) than for the conventional simulator ( η 2 = 0.10). Within-group analysis revealed no significant pairwise differences across all attempts for the commercial simulator. In contrast, several pairwise comparisons remained statistically significant for the in-house simulator (attempts 1 vs. 3, 1 vs. 4, 2 vs. 5, and 1 vs. 5), all with large effect sizes (Cohen’s d > 1.1). Between-group comparison of individual LEEP scores showed a statistically significant difference in the fifth attempt ( p = 0.002), with a large effect size (Cohen’s d = 1.01) favoring the in-house simulator. Higher R0 resection rates were observed with the in-house simulator in the third (100% vs. 83.3%) and fourth attempts (96.7% vs. 73.3%). Blinded video assessments by two senior experts confirmed these findings, demonstrating higher checklist, Global Rating Scale (GRS), and overall mean scores for the in-house simulator from the third attempt onward (all p < 0.05; all Cohen’s d > 0.8). Participant feedback further supported these results, indicating improved confidence, technical skills, and perceived educational value.
Conclusion
This study demonstrated that the novel in-house 3D-printed simulator significantly outperformed the commercial model in objective surgical performance, learning progression and user satisfaction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany. quenzer_a@ukw.de.
- Department of Obstetrics and Gynecology, University Hospital of Wuerzburg, Josef-Schneider-Strasse 4, 97080, Würzburg, Germany.
- Department of Radiology, University Hospital Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
- Translational Oncology, Comprehensive Cancer Center Mainfranken, University Hospital Wuerzburg, Josef-Schneider-Str. 6, 97080, Würzburg, Germany.
ORCID-Profile: Anne Cathrine Scherer-Quenzer, Matthias Kiesel
Förderung
- Universitätsklinikum Würzburg
Zitieren
APA
Scherer-Quenzer, A. C., Reinhart, K., Diessner, J., Altides, A., Buechel, J., Blau-Schneider, B., Sauer, S. T., Deschler-Baier, B., Woeckel, A., & Kiesel, M. (2026). Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model. Archives of Gynecology and Obstetrics, 313(1). https://doi.org/10.1007/s00404-026-08413-3
Vancouver
Scherer-Quenzer AC, Reinhart K, Diessner J, Altides A, Buechel J, Blau-Schneider B, et al. Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model. Archives of Gynecology and Obstetrics. 2026;313(1). doi:10.1007/s00404-026-08413-3
BibTeX
@article{SchererQuenzer2026,
author = {Scherer-Quenzer, Anne Cathrine and Reinhart, Katharina and Diessner, Joachim and Altides, Anastasia and Buechel, Johanna and Blau-Schneider, Bettina and Sauer, Stephanie Tina and Deschler-Baier, Barbara and Woeckel, Achim and Kiesel, Matthias},
title = {Comparative validation of a cost-effective in-house 3D-printed LLETZ simulator versus a commercial training model},
journal = {Archives of Gynecology and Obstetrics},
year = {2026},
volume = {313},
number = {1},
doi = {10.1007/s00404-026-08413-3}
}
EUVIMED