A randomized prospective study to compare the efficacy of 308-nm light-emitting diode and 308-nm excimer lamp in the treatment of facial vitiligo
Archives of Dermatological Research · 2025
DOI: 10.1007/s00403-024-03721-7 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Archives of Dermatological Research, 2025. Verfasst von Yu Hu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China. Hauptthemen laut MEDLINE: Vitiligo. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: the National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Previous studies have proven that 308-nm light-emitting diode(308-nm LED)and 308-nm excimer lamp(308-nm MEL) are effective in treating vitiligo, but there is a lack of comparison of their efficacy for facial lesions. OBJECTIVE: To evaluate and contrast the treatment success rates of 308-nm LED versus 308-nm excimer lamp in managing facial lesions among patients suffering from stable non-segmental vitiligo. METHODS: The enrolled 119 patients with 145 lesions were randomly assigned to receive 308-nm LED or 308-nm MEL for two months. Two independent investigators graded repigmentation at the end of the 2-month treatment period. RESULTS: There were 76 lesions in the 308-nm LED group and 69 in the 308-nm MEL group. After 1 month, the average repigmentation grade of the 308-nm LED group was 1.34, with an efficacy rate of 11.84%, and the average repigmentation grade of the 308-nm MEL group was 1.17, with an efficacy rate of 7.24%.After two months of phototherapy, the average repigmentation grade of the 308-nm LED group was 2.38, and the effective rate was 42.1%. The average repigmentation grade in the 308-nm MEL group was 2.19, and the effective rate was 39.12%. The two light sources had similar effects on facial vitiligo lesions after 1 month and 2 months of treatment(P =.349, P =.416), and the incidence of side effects was also comparable between the two groups (P =.332). CONCLUSION: The 308-nm LED is as effective and safe as 308-nm MEL in treating stable non-segmental facial vitiligo lesions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiotherapy, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China.
- Hospital for Skin Diseases, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China.
- Department of Physiotherapy, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China. hd061111@163.com.
- Department of Physiotherapy, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China. jazhang618@126.com.
- Department of Physiotherapy, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Nanjing, 210042, China. kunchen181@aliyun.com.
Förderung
- the National Natural Science Foundation of China
Zitieren
APA
Hu, Y., Xu, Z., Liu, L., Ju, M., Luan, C., Chen, H., Chen, L., Dai, X., Zhang, L., Huang, D., Zhang, J., & Chen, K. (2025). A randomized prospective study to compare the efficacy of 308-nm light-emitting diode and 308-nm excimer lamp in the treatment of facial vitiligo. Archives of Dermatological Research. https://doi.org/10.1007/s00403-024-03721-7
Vancouver
Hu Y, Xu Z, Liu L, Ju M, Luan C, Chen H, et al. A randomized prospective study to compare the efficacy of 308-nm light-emitting diode and 308-nm excimer lamp in the treatment of facial vitiligo. Archives of Dermatological Research. 2025. doi:10.1007/s00403-024-03721-7
BibTeX
@article{Hu2025,
author = {Hu, Yu and Xu, Zhuohong and Liu, Lihao and Ju, Mei and Luan, Chao and Chen, Hongying and Chen, Lihao and Dai, Xiaoxi and Zhang, Liangliang and Huang, Dan and Zhang, Jiaan and Chen, Kun},
title = {A randomized prospective study to compare the efficacy of 308-nm light-emitting diode and 308-nm excimer lamp in the treatment of facial vitiligo},
journal = {Archives of Dermatological Research},
year = {2025},
doi = {10.1007/s00403-024-03721-7}
}