Interrater reproducibility of the Myoton and durometer devices to quantify sclerotic chronic graft-versus-host disease
Archives of Dermatological Research · 2023
DOI: 10.1007/s00403-023-02626-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Dermatological Research, 2023. Verfasst von Shramana Ghosh und 10 weiteren Autor:innen. Beteiligte Einrichtung: Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA. Hauptthemen laut MEDLINE: Bronchiolitis Obliterans Syndrome, Skin Diseases, Graft vs Host Disease. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: CSRD VA, NCI NIH HHS, NIH HHS.
Abstract (Originalsprache)
Chronic graft-versus-host disease (cGVHD) is a severe complication in long-term survivors of allogeneic hematopoietic stem cell transplantation. This disease is challenging to manage clinically due to a lack of validated tools to quantitatively measure skin sclerosis. The current gold standard for measuring skin sclerosis is the NIH Skin Score which has only moderate agreement among clinicians and experts. To more accurately assess skin sclerosis in cGVHD, the Myoton and durometer devices can be used to directly measure biomechanical parameters of the skin. However, the reproducibility of these devices is not known in patients with cGVHD. To determine this reproducibility, three observers independently measured 10 anatomic sites in each of seven patients with sclerotic cGVHD using the Myoton and durometer. Clinical reproducibility was measured by mean pairwise differences (U-statistic) and intraclass correlation coefficients (ICCs) with 95% confidence intervals (CIs). Mean pairwise differences, expressed in true physical units, were used to report typical errors for each anatomic site and device. Mean pairwise differences were less than 11% of the average overall values for all five Myoton parameters and durometer hardness. These were lower for Myoton creep (4.1%), relaxation time (4.7%), and frequency (5.1%) than decrement (9.0%), stiffness (10.4%), and durometer hardness (9.0%). Myoton parameters creep, relaxation time, and frequency showed promise for capturing skin biomechanics more accurately than Myoton stiffness, decrement, or durometer hardness. Mean pairwise differences trended highest in the shin and volar forearm and lowest in the dorsal forearm. The interobserver ICC for overall (averaged across all measured body sites of a patient) creep (0.94; 95% CI 0.87-1.00), relaxation time (0.96; 95% CI 0.90-1.00), and frequency (0.95; 95% CI 0.88-1.00), trended higher than that for decrement (0.43; 95% CI 0.00-0.88), stiffness (0.92; 95% CI 0.81-1.00), and durometer hardness (0.82; 95% CI 0.61-1.00). Similar trends were observed in healthy participants. These findings can help clinicians design better studies to assess therapeutic response to new cGVHD treatments and support the interpretation of future measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dermatology and Research Services, Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA.
- Vanderbilt Dermatology Translational Research Clinic, Department of Dermatology, Vanderbilt University Medical Center, TN, Nashville, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.
- Medical Scientist Training Program, Yale School of Medicine, New Haven, CT, USA.
- University of Tartu Institute of Physics, Tartu, Estonia.
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN, USA.
Förderung
- CSRD VA
- NCI NIH HHS
- NIH HHS
- U.S. Department of Veterans Affairs
- National Institutes of Health
Zitieren
APA
Ghosh, S., Baker, L., Chen, F., Khera, Z., Vain, A., Zhang, K., Hood, A., Smith, H., Chen, H., Jagasia, M., & Tkaczyk, E. (2023). Interrater reproducibility of the Myoton and durometer devices to quantify sclerotic chronic graft-versus-host disease. Archives of Dermatological Research. https://doi.org/10.1007/s00403-023-02626-1
Vancouver
Ghosh S, Baker L, Chen F, Khera Z, Vain A, Zhang K, et al. Interrater reproducibility of the Myoton and durometer devices to quantify sclerotic chronic graft-versus-host disease. Archives of Dermatological Research. 2023. doi:10.1007/s00403-023-02626-1
BibTeX
@article{Ghosh2023,
author = {Ghosh, Shramana and Baker, Laura and Chen, Fuyao and Khera, Zain and Vain, Arved and Zhang, Kathy and Hood, Alexis and Smith, Hayden and Chen, Heidi and Jagasia, Madan and Tkaczyk, Eric},
title = {Interrater reproducibility of the Myoton and durometer devices to quantify sclerotic chronic graft-versus-host disease},
journal = {Archives of Dermatological Research},
year = {2023},
doi = {10.1007/s00403-023-02626-1}
}