EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Radiographic accuracy of implant positioning in unicompartmental knee arthroplasty, does an imageless robotic system make a difference?

Alice Montagna, Luca Andriollo, Virginia Cinelli, Marina Marescalchi, Luca Matascioli, Francesco Benazzo, Stefano Marco Paolo Rossi

Archives of Orthopaedic and Trauma Surgery · 2026

DOI: 10.1007/s00402-026-06499-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2026. Verfasst von Alice Montagna und 6 weiteren Autor:innen. Beteiligte Einrichtung: Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Knee Prosthesis, Knee Joint. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Robotic-assisted technologies and evolving implant designs have been introduced in unicompartmental knee arthroplasty (UKA) to improve the accuracy and reproducibility of component positioning. However, the relative contribution of robotic assistance compared with conventional instrumentation to radiographic outcomes in experienced, high-volume centers remains unclear.

Methods

This retrospective comparative study included 96 consecutive medial UKAs performed at a single high-volume institution. Patients were stratified into three groups: Journey I UKA implanted with NAVIO imageless robotic assistance ( n = 38), Journey II Uni UKA implanted using conventional instrumentation ( n = 27), and Journey II UK UKA implanted with CORI imageless robotic assistance ( n = 31). Standardized standing long-leg weight-bearing radiographs were obtained preoperatively and postoperatively. Radiographic evaluation included hip–knee–ankle (HKA) angle, femoral component coronal angle (FCCA), tibial component coronal angle (TCCA), and sagittal alignment parameters. Tibial coronal alignment was interpreted according to the Cartier metaphyseal alignment philosophy. Intergroup comparisons were performed using appropriate statistical tests.

Results

Baseline demographic characteristics and preoperative radiographic parameters were comparable among the three groups (all p > 0.05). Postoperative mean HKA was 177.1° ± 2.1° in the Journey I NAVIO group, 177.3° ± 2.5° in the Journey II Uni conventional group, and 177.7° ± 2.2° in the Journey II UK CORI group, with no statistically significant differences ( p = 0.56). Femoral and tibial component coronal alignment, including TCCA, showed no significant intergroup differences. All cases across the three cohorts were within predefined safe zones for HKA, FCCA, and TCCA. Sagittal alignment parameters were also comparable between groups.

Conclusion

In a high-volume center adopting a consistent alignment philosophy, medial UKA achieves equivalent and highly accurate radiographic outcomes regardless of robotic assistance or conventional instrumentation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresKnee ProsthesisKnee JointHumansRetrospective StudiesRadiographyFemaleMaleAgedMiddle Aged

Stichwörter der Autor:innen

Coronal alignmentImplant positioningRadiographic alignmentRobotic-assisted surgeryUnicompartmental knee arthroplasty

Autor:innen und Institutionen

  • Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy.
  • Policlinico San Matteo Fondazione, Pavia, Italy.
  • Catholic University of the Sacred Heart, Rome, Italy. andriollo.luca@gmail.com.
  • Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy. andriollo.luca@gmail.com.
  • Catholic University of the Sacred Heart, Rome, Italy.
  • Istituto Universitario di Studi Superiori di Pavia, Pavia, Italy.

Zitieren

APA

Montagna, A., Andriollo, L., Cinelli, V., Marescalchi, M., Matascioli, L., Benazzo, F., & Rossi, S. M. P. (2026). Radiographic accuracy of implant positioning in unicompartmental knee arthroplasty, does an imageless robotic system make a difference?. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-026-06499-7

Vancouver

Montagna A, Andriollo L, Cinelli V, Marescalchi M, Matascioli L, Benazzo F, et al. Radiographic accuracy of implant positioning in unicompartmental knee arthroplasty, does an imageless robotic system make a difference?. Archives of Orthopaedic and Trauma Surgery. 2026. doi:10.1007/s00402-026-06499-7

BibTeX
@article{Montagna2026,
  author = {Montagna, Alice and Andriollo, Luca and Cinelli, Virginia and Marescalchi, Marina and Matascioli, Luca and Benazzo, Francesco and Rossi, Stefano Marco Paolo},
  title = {Radiographic accuracy of implant positioning in unicompartmental knee arthroplasty, does an imageless robotic system make a difference?},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  doi = {10.1007/s00402-026-06499-7}
}
Kostenlos starten →