Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation
Archives of Orthopaedic and Trauma Surgery · 06.08.2026 · 146 (1)
DOI: 10.1007/s00402-026-06464-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 06.08.2026. Verfasst von Yasutaka Masada und 7 weiteren Autor:innen. Beteiligte Einrichtung: Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Department of Orthopaedic Surgery, Graduate School of Medicine, Den…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Tomography, X-Ray Computed, Bone Nails, Ilium. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Okayama University.
Abstract (Originalsprache)
Introduction
Accurate iliac crest reference pin placement is essential for safe navigation-assisted total hip arthroplasty (THA). Although complications are uncommon, inaccurate placement may cause neurovascular injury. This study aimed to evaluate pin insertion accuracy using postoperative computed tomography (CT), identify risk factors for cortical perforation, and determine whether CT-detected cortical perforation was associated with postoperative acetabular cup positioning accuracy. Materials and methods We retrospectively analyzed 200 primary THAs performed using portable or CT-based navigation between December 2022 and July 2025. Pin position was assessed on CT 1 week postoperatively and classified as complete intraosseous insertion or cortical perforation. Risk factors were examined using univariable and multivariable logistic regression analyses. Perforation direction was evaluated using Firth’s penalized logistic regression. Postoperative cup positioning accuracy was assessed using CT-based radiographic inclination (RI), radiographic anteversion (RA), and absolute errors from target angles of 40° for RI and 15° for RA.
Results
Cortical perforation occurred in 70 of 200 hips (35.0%): 32 medial and 38 lateral. On a pin-by-pin basis, 113 of 400 pins (28.3%) demonstrated perforation. In multivariable analysis, smaller ASIS width, lateral decubitus positioning, and 4-mm pin use independently predicted cortical perforation. Medial perforation was independently associated with lateral decubitus positioning, 4-mm pin use, and smaller iliac wing angle in Firth’s model. RI, RA, absolute RI error, and absolute RA error did not differ significantly between the intraosseous and cortical perforation groups. All hips in both groups were within 10° of the target angles for both RI and RA. No dislocation or revision surgery occurred in either group.
Conclusions
CT-detected cortical perforation of iliac crest reference pins was common but was rarely accompanied by clinically apparent complications and was not associated with inferior postoperative cup positioning accuracy. Perforation risk was influenced by insertion position, platform-associated instrumentation, and pelvic morphology. These findings should be interpreted primarily as a technical accuracy endpoint rather than as evidence of clinically proven harm. The clinical significance of CT-detected cortical perforation remains uncertain, and particular attention should be paid to minimizing medial cortical breach.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Department of Orthopaedic Surgery, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-…
- Department of Musculoskeletal Health Promotion, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan. tomonori_t31@yahoo.co.jp.
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan.
- Department of Sports Medicine, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan.
- Center for Education in Medicine and Health Sciences, Okayama University, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan.
ORCID-Profile: Tomonori Tetsunaga
Förderung
- Okayama University
Zitieren
APA
Masada, Y., Tetsunaga, T., Yamada, K., Inoue, T., Okuda, R., Tetsunaga, T., Okazaki, Y., & Ozaki, T. (2026). Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06464-4
Vancouver
Masada Y, Tetsunaga T, Yamada K, Inoue T, Okuda R, Tetsunaga T, et al. Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06464-4
BibTeX
@article{Masada2026,
author = {Masada, Yasutaka and Tetsunaga, Tomonori and Yamada, Kazuki and Inoue, Tomohiro and Okuda, Ryuichiro and Tetsunaga, Tomoko and Okazaki, Yuki and Ozaki, Toshifumi},
title = {Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
volume = {146},
number = {1},
doi = {10.1007/s00402-026-06464-4}
}
EUVIMED