EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures

Lena Dietz, Christian Spiegel, Felix Christian Kohler, Uta Biedermann, Ivan Zderic, Alicia Feist, Boyko Gueorguiev-Rüegg, Mark Lenz, Wolfram Weschenfelder

Archives of Orthopaedic and Trauma Surgery · 10.08.2026 · 146 (1)

DOI: 10.1007/s00402-026-06454-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 10.08.2026. Verfasst von Lena Dietz und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma, Hand and Reconstructive Surgery and Orthopaedics, Jena University Hospital, Jena, Germany. Hauptthemen laut MEDLINE: Radius Fractures, Bone Screws, Fracture Fixation, Internal, Wrist Fractures. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Jena.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the biomechanical influence of distal screw number in palmar plate fixation of unstable intra-articular distal radius fractures with radiodorsal metaphyseal comminution.

Methods

Nine matched pairs of cryopreserved human radii were prepared using a standardized AO/OTA 2R3 C2.1 fracture model with a defined radiodorsal metaphyseal defect zone. For each pair, specimens were randomized to palmar fixation using a 2.4-mm variable-angle locking plate with either four or six distal screws. After embedding, constructs were subjected to cyclic axial loading (150 N, 5,000 cycles) simulating early postoperative rehabilitation. Global axial deformation and fragment-specific three-dimensional interfragmentary motion were recorded using an optical motion-tracking system. Statistical analysis was performed using non-parametric tests ( p < 0.05).

Results

Two specimens from one donor pair were excluded, leaving 16 radii (8 pairs) for analysis. Bone mineral density and initial construct stiffness did not differ between groups. The six-screw configuration showed significantly lower axial deformation after cyclic loading ( p = 0.047) and lower radial fragment–shaft translation at both time points ( p = 0.028; p = 0.045). Radial fragment–shaft rotation was lower in the six-screw group at baseline ( p = 0.018), but no rotational difference remained after cyclic loading. In the overall cohort, axial deformation decreased after cyclic loading ( p = 0.015).

Conclusion

In this unstable intra-articular fracture model with radiodorsal metaphyseal comminution, six distal screws reduced post-cyclic axial deformation and radial fragment–shaft micromotion compared with four screws. The clinical relevance of these findings remains to be determined.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radius FracturesBone ScrewsFracture Fixation, InternalWrist FracturesHumansBiomechanical PhenomenaBone PlatesFemaleMale

Stichwörter der Autor:innen

Distal radius fracturefracture fixationpalmar locking platescrew number

Autor:innen und Institutionen

  • Department of Trauma, Hand and Reconstructive Surgery and Orthopaedics, Jena University Hospital, Jena, Germany.
  • Institute of Anatomy I, Jena University Hospital, Jena, Germany.
  • AO Research Institute Davos, AO Foundation, Davos, Switzerland.
  • Department of Trauma, Hand and Reconstructive Surgery and Orthopaedics, Jena University Hospital, Jena, Germany. mark.lenz@med.uni-jena.de.

Förderung

  • Universitätsklinikum Jena

Zitieren

APA

Dietz, L., Spiegel, C., Kohler, F. C., Biedermann, U., Zderic, I., Feist, A., Gueorguiev-Rüegg, B., Lenz, M., & Weschenfelder, W. (2026). Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06454-6

Vancouver

Dietz L, Spiegel C, Kohler FC, Biedermann U, Zderic I, Feist A, et al. Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06454-6

BibTeX
@article{Dietz2026,
  author = {Dietz, Lena and Spiegel, Christian and Kohler, Felix Christian and Biedermann, Uta and Zderic, Ivan and Feist, Alicia and Gueorguiev-Rüegg, Boyko and Lenz, Mark and Weschenfelder, Wolfram},
  title = {Effect of distal screw number on axial deformation and fragment-specific stability in AO/OTA 2R3 C2.1 distal radius fractures},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  volume = {146},
  number = {1},
  doi = {10.1007/s00402-026-06454-6}
}
Kostenlos starten →