Subclinical median nerve alterations after distal radius fractures: a comparative analysis of volar plate fixation and cast immobilization using dynamic ultrasonography and electrophysiology
Archives of Orthopaedic and Trauma Surgery · 27.05.2026 · 146 (1)
DOI: 10.1007/s00402-026-06364-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 27.05.2026. Verfasst von Sefa Erdem Karapinar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Süleyman Demirel University, Isparta, Turkey. sefaerdemkarapinar@gmail.com. Hauptthemen laut MEDLINE: Radius Fractures, Median Nerve, Casts, Surgical, Fracture Fixation, Internal. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Suleyman Demirel University.
Abstract (Originalsprache)
Background
Distal radius fractures may affect the median nerve through trauma-related and treatment-related mechanisms. While overt neurological deficits are uncommon, subclinical median nerve alterations may occur following both conservative and surgical treatment.
Purpose
To determine whether treatment modality influences subclinical median nerve behavior using combined dynamic ultrasonographic and electrophysiological assessment.
Methods
This retrospective observational study included 42 patients with unilateral distal radius fractures. 18 patients were treated conservatively with circular casting, and 24 patients underwent volar plate fixation. Ultrasonographic assessment of the median nerve was performed at the distal radius level in neutral wrist position, as well as during wrist flexion and extension, using a dynamic ultrasonographic approach, and was combined with electrophysiological evaluation including sensory and motor nerve conduction studies. In the surgically treated group, only patients with Soong type 1 or type 2 plate positioning were included.
Results
Clinical functional outcome scores were comparable between groups, despite a higher frequency of mild clinical signs such as positive Tinel test and night pain in the plate group. However, ultrasonographic evaluation demonstrated significantly greater position-dependent median nerve enlargement and flattening in the volar plate group, particularly during wrist flexion and extension ( p < 0.05). Electrophysiological assessment revealed a significant reduction in sensory nerve conduction velocity on the affected side in surgically treated patients compared with the cast group ( p < 0.05), while motor conduction parameters remained preserved. These differences were observed despite comparable clinical functional outcomes between groups.
Conclusion
Patients treated with volar plate fixation demonstrated more pronounced subclinical ultrasonographic and electrophysiological median nerve alterations compared with those treated conservatively with cast immobilization. However, given the retrospective and non-randomized design, these findings should be interpreted as associative rather than causal. Combined ultrasonographic and electrophysiological assessment may be useful for detecting early median nerve involvement and guiding follow-up evaluation, even in the absence of clinically overt symptoms.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Süleyman Demirel University, Isparta, Turkey. sefaerdemkarapinar@gmail.com.
- Department of Sports Medicine, Süleyman Demirel University, Isparta, Turkey.
- Department of Emergency Medicine, Süleyman Demirel University, Isparta, Turkey.
- Department of Orthopedics and Traumatology, Süleyman Demirel University, Isparta, Turkey.
- Department of Neurology, Süleyman Demirel University, Isparta, Turkey.
- Department of Orthopedics and Traumatology, Private Metrolife Hospital, Sanliurfa, Turkey.
Förderung
- Suleyman Demirel University
Zitieren
APA
Karapinar, S. E., Arslan, E., Oguzlar, F. C., Hatip, A. Y., Akgun, V. O., Dincer, R., Asci, S., & Kizilkaya, V. (2026). Subclinical median nerve alterations after distal radius fractures: a comparative analysis of volar plate fixation and cast immobilization using dynamic ultrasonography and electrophysiology. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06364-7
Vancouver
Karapinar SE, Arslan E, Oguzlar FC, Hatip AY, Akgun VO, Dincer R, et al. Subclinical median nerve alterations after distal radius fractures: a comparative analysis of volar plate fixation and cast immobilization using dynamic ultrasonography and electrophysiology. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06364-7
BibTeX
@article{Karapinar2026,
author = {Karapinar, Sefa Erdem and Arslan, Esma and Oguzlar, Furkan Cagri and Hatip, Ahmet Yunus and Akgun, Vedat Onur and Dincer, Recep and Asci, Sanem and Kizilkaya, Volkan},
title = {Subclinical median nerve alterations after distal radius fractures: a comparative analysis of volar plate fixation and cast immobilization using dynamic ultrasonography and electrophysiology},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
volume = {146},
number = {1},
doi = {10.1007/s00402-026-06364-7}
}
EUVIMED