EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Double-row wired anchors combined with “8” cross tension bands: an innovative procedure for the treatment of inferior pole fractures of the patella and its finite element and biomechanical evaluation

Zihao Deng, Wei Zhang, Jian Chen, Zilong Yang, Wentao Gao, Yuxuan Liu, Xiping Zhang, Wei Zeng, Zhiqin Liu

Archives of Orthopaedic and Trauma Surgery · 20.04.2026 · 146 (1)

DOI: 10.1007/s00402-026-06283-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 20.04.2026. Verfasst von Zihao Deng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Trauma Center Department Three, Zhuzhou Hospital Affiliated to Xiangya School of Medicin, Central South University, Zhuzhou, Hunan, China. Hauptthemen laut MEDLINE: Patella Fracture, Fracture Fixation, Internal, Bone Wires, Suture Anchors. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To propose and verify the biomechanical properties of a new double-row suture anchor combined with figure-of-eight cross tension band technology for the treatment of inferior pole fractures of the patella, in order to overcome the shortcomings of traditional fixation methods in achieving stable fixation and reducing implant-related complications.

Methods

(1) Based on clinical CT data, a three-dimensional finite element model of patellar inferior pole fracture was reconstructed, and the new fixation technology (deep double-row anchors in the proximal bone fragment combined with figure-of-8 sutures) and Kirschner wire tension band wire fixation (TBW) were simulated and analyzed. Mechanical performance in the treatment of inferior pole fracture of the patella; (2) Divide the model into two groups according to surgical methods: suture anchor (SA) fixation group and TBW fixation group; (3) Carry out finite element analysis to compare the two groups at 500 Displacement and stress distribution of the knee joint at 45°and 135°of flexion under N load.

Results

Finite element analysis and biomechanical test results showed that there was no significant difference in displacement and stress between the two groups at different flexion angles.

Conclusion

Double-row anchors combined with figure-of-eight suture technology exhibited excellent biomechanical properties, and is a feasible fixation solution for the treatment of inferior pole fractures of the patella.This technology can significantly reduce stress concentration and the risk of implant complications, providing a minimally invasive solution to replace traditional metal implants and helping patients recover early, but its long-term efficacy still requires further clinical verification.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Patella FractureFracture Fixation, InternalBone WiresSuture AnchorsPatellaHumansFinite Element AnalysisBiomechanical PhenomenaTomography, X-Ray Computed

Stichwörter der Autor:innen

AnchorFinite element analysisInferior poleMechanical analysisPatellar fracture

Autor:innen und Institutionen

  • Trauma Center Department Three, Zhuzhou Hospital Affiliated to Xiangya School of Medicin, Central South University, Zhuzhou, Hunan, China.
  • Trauma Center Department Four, Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou, Hunan, China.
  • People's Hospital of Lukou District, Zhuzhou, Hunan, China.
  • Trauma Center Department Three, Zhuzhou Hospital Affiliated to Xiangya School of Medicin, Central South University, Zhuzhou, Hunan, China. zhiqin_liu@csu.edu.cn.

Förderung

  • Natural Science Foundation of Hunan Province

Zitieren

APA

Deng, Z., Zhang, W., Chen, J., Yang, Z., Gao, W., Liu, Y., Zhang, X., Zeng, W., & Liu, Z. (2026). Double-row wired anchors combined with “8” cross tension bands: an innovative procedure for the treatment of inferior pole fractures of the patella and its finite element and biomechanical evaluation. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06283-7

Vancouver

Deng Z, Zhang W, Chen J, Yang Z, Gao W, Liu Y, et al. Double-row wired anchors combined with “8” cross tension bands: an innovative procedure for the treatment of inferior pole fractures of the patella and its finite element and biomechanical evaluation. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06283-7

BibTeX
@article{Deng2026,
  author = {Deng, Zihao and Zhang, Wei and Chen, Jian and Yang, Zilong and Gao, Wentao and Liu, Yuxuan and Zhang, Xiping and Zeng, Wei and Liu, Zhiqin},
  title = {Double-row wired anchors combined with “8” cross tension bands: an innovative procedure for the treatment of inferior pole fractures of the patella and its finite element and biomechanical evaluation},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  volume = {146},
  number = {1},
  doi = {10.1007/s00402-026-06283-7}
}
Kostenlos starten →