EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In vivo kinematics of knee joint cartilage and meniscus contact areas under load application: a biomechanical MRI study

Moritz Florian Mayr, Hans Meine, Thomas Lange, Tayfun Yilmaz, Elham Taghizadeh, Hagen Schmal, Kaywan Izadpanah

Archives of Orthopaedic and Trauma Surgery · 2026

DOI: 10.1007/s00402-026-06234-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2026. Verfasst von Moritz Florian Mayr und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Freiburg, Germany. moritz.mayr@uniklinik-freiburg.de. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cartilage, Articular, Menisci, Tibial, Knee Joint. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Distinguishing physiological meniscus mobility from pathological extrusion remains a clinical challenge, particularly regarding the prevention of osteoarthritis. While cadaveric studies suggest that meniscectomy increases contact stress, the in vivo dynamics of the healthy meniscus under load—specifically the role of the meniscotibial (coronary) ligament—remain poorly defined. This study aimed to establish a physiological reference standard for load transmission and contact area kinematics in the healthy knee.

Methods

In a biomechanical MRI study, nine healthy male subjects underwent high-resolution 3T MRI with prospective motion correction. Knee joints were scanned in an unloaded state and under a physiological axial load of 400 N. We performed 3D segmentation to quantify changes in cartilage-to-cartilage and cartilage-to-meniscus contact areas, differentiating between femoral and tibial interfaces.

Results

Axial loading significantly increased the direct cartilage-to-cartilage contact area, with a predominant increase in the medial compartment (+ 15.0%) compared to the lateral compartment (+ 6.7%), reflecting the physiological adduction moment. Conversely, the overall meniscus-to-cartilage contact area decreased. A detailed compartmental analysis revealed a distinct kinematic pattern: while the femoral-meniscal contact area significantly decreased due to relative motion, the tibial-meniscal contact area remained stable.

Conclusion

This study defines the in vivo healthy baseline of knee contact mechanics. The results demonstrate that under physiological load, the healthy meniscus undergoes controlled radial displacement to facilitate direct cartilage contact. Crucially, the stability of the tibial contact area supports the hypothesis that the meniscotibial (coronary) ligament acts as a primary anchor, preventing excessive extrusion at the tibial interface. These data serve as a vital benchmark for evaluating meniscus repair techniques and differentiating physiological mobility from pathological failure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingCartilage, ArticularMenisci, TibialKnee JointHumansMaleBiomechanical PhenomenaWeight-BearingAdultTibiofemoral Joint

Stichwörter der Autor:innen

BiomechanicsContact areaImagingKnee jointMRIMeniscal extrusionMeniscus

Autor:innen und Institutionen

  • Department of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Freiburg, Germany. moritz.mayr@uniklinik-freiburg.de.
  • MEVIS, Fraunhofer Institute for Digital Medicine, Bremen, Germany.
  • Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Freiburg, Germany.
  • Department of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Freiburg, Germany.
  • Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark.

Förderung

  • Universitätsklinikum Freiburg

Zitieren

APA

Mayr, M. F., Meine, H., Lange, T., Yilmaz, T., Taghizadeh, E., Schmal, H., & Izadpanah, K. (2026). In vivo kinematics of knee joint cartilage and meniscus contact areas under load application: a biomechanical MRI study. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-026-06234-2

Vancouver

Mayr MF, Meine H, Lange T, Yilmaz T, Taghizadeh E, Schmal H, et al. In vivo kinematics of knee joint cartilage and meniscus contact areas under load application: a biomechanical MRI study. Archives of Orthopaedic and Trauma Surgery. 2026. doi:10.1007/s00402-026-06234-2

BibTeX
@article{Mayr2026,
  author = {Mayr, Moritz Florian and Meine, Hans and Lange, Thomas and Yilmaz, Tayfun and Taghizadeh, Elham and Schmal, Hagen and Izadpanah, Kaywan},
  title = {In vivo kinematics of knee joint cartilage and meniscus contact areas under load application: a biomechanical MRI study},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  doi = {10.1007/s00402-026-06234-2}
}
Kostenlos starten →