EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The ulna osteotomy locking plate II in patients with ulnocarpal impaction syndrome: a retrospective evaluation

Stefan Benedikt, Ulrike Seeher, Moritz Stricker, Simone Bode, Kerstin Stock, Rohit Arora

Archives of Orthopaedic and Trauma Surgery · 17.03.2026 · 146 (1)

DOI: 10.1007/s00402-026-06223-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, online erschienen am 17.03.2026. Verfasst von Stefan Benedikt und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Innsbruck Medical University, Innsbruck, Austria. Hauptthemen laut MEDLINE: Osteotomy, Bone Plates, Ulna, Wrist Joint. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Innsbruck and Medical University of Innsbruck.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Ulnocarpal impaction syndrome is one general cause of ulnar-sided wrist pain. If conservative therapy fails, various surgical procedures and different instruments and implants are available. The aim of this study was to evaluate the results of the ulna osteotomy locking (UOL) plate II from the manufacturer I.T.S. Materials and methods Thirty-five cases (34 patients) with primary or secondary ulnar impaction syndrome treated with the UOL plate II were evaluated retrospectively. Demographic, radiologic and clinical data were collected focusing on the postoperative ulnar variance and the complication rate, especially non-unions and signs of implant failure.

Results

Median age was 48 years, with 20 female and 15 male cases. The measured median postoperative ulnar variance was − 0.8 mm (Q1: − 2; Q3: 0). There was no case of a non-union or a postoperative infection. Postoperative complications included one case of secondary dislocation, one case of a neuroma of the dorsal branch of the ulnar nerve and one mild CRPS. A total of six cases wished for an implant removal in the follow-up, of which five complained about local irritation caused by the plate.

Conclusions

The UOL plate II has proven to be a reliable option for ulnar shortening osteotomy with a low implant associated complication rate, especially no case of non-union. The occasional need for implant removal should be considered. Due to the retrospective study design, a prospective study comparing the UOL II plate to different plating systems would be desirable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsteotomyBone PlatesUlnaWrist JointHumansRetrospective StudiesFemaleMaleMiddle AgedAdultSyndromeAged

Stichwörter der Autor:innen

DiscusMalunionShorteningTFCCTolatUlnar wrist painUlnocarpal impaction syndrome

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Innsbruck Medical University, Innsbruck, Austria.
  • Department of Orthopaedics and Traumatology, Innsbruck Medical University, Innsbruck, Austria. ulrike.seeher@tirol-kliniken.at.

Förderung

  • University of Innsbruck and Medical University of Innsbruck

Zitieren

APA

Benedikt, S., Seeher, U., Stricker, M., Bode, S., Stock, K., & Arora, R. (2026). The ulna osteotomy locking plate II in patients with ulnocarpal impaction syndrome: a retrospective evaluation. Archives of Orthopaedic and Trauma Surgery, 146(1). https://doi.org/10.1007/s00402-026-06223-5

Vancouver

Benedikt S, Seeher U, Stricker M, Bode S, Stock K, Arora R. The ulna osteotomy locking plate II in patients with ulnocarpal impaction syndrome: a retrospective evaluation. Archives of Orthopaedic and Trauma Surgery. 2026;146(1). doi:10.1007/s00402-026-06223-5

BibTeX
@article{Benedikt2026,
  author = {Benedikt, Stefan and Seeher, Ulrike and Stricker, Moritz and Bode, Simone and Stock, Kerstin and Arora, Rohit},
  title = {The ulna osteotomy locking plate II in patients with ulnocarpal impaction syndrome: a retrospective evaluation},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2026},
  volume = {146},
  number = {1},
  doi = {10.1007/s00402-026-06223-5}
}
Kostenlos starten →