Intraoperative evaluation of rotational alignment in minimally invasive plate osteosynthesis for humeral shaft fractures using combined fluoroscopic and endoscopic assistance: surgical technique, clinical outcomes, and literature review
Archives of Orthopaedic and Trauma Surgery · 2026
DOI: 10.1007/s00402-025-06170-7 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2026. Verfasst von Chang-Heng Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan. Hauptthemen laut MEDLINE: Humeral Fractures, Fracture Fixation, Internal, Bone Plates, Endoscopy. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
INTRODUCTION: Minimally invasive plate osteosynthesis (MIPO) has become an established method for treating humeral shaft fractures; however, achieving accurate intraoperative rotational alignment remains challenging. This study describes an intraoperative evaluation technique using combined fluoroscopic and endoscopic assistance to improve the precision and objectivity of rotational correction during MIPO. MATERIALS AND METHODS: From September 2019 to June 2023, twenty adult patients with simple transverse or wedge-type midshaft humeral fractures (AO/OTA type A or B) who underwent MIPO fixation were retrospectively reviewed. Demographic data, operative time, intraoperative fluoroscopy time, and postoperative outcomes were analyzed. Rotational difference (RD) between the operated and contralateral arms was measured using computed tomography (CT). Continuous variables between AO type A and B fractures were compared using the Mann–Whitney U test (p < 0.05). RESULTS: The mean operative time was 113.5 min, and the mean fluoroscopy time was 75.9 s, which was significantly longer in AO type B fractures (p < 0.05). The average RD was 7.4° ± 4.7° (range, 1.9˚–17.5°). All fractures achieved union, with 18 cases healing within 3–6 months and 2 cases within 9–12 months. Mean angulation was 2.1° (coronal) and 2.0° (sagittal), and mean translation was 1.1 mm (coronal) and 1.3 mm (sagittal). No iatrogenic neurovascular injuries or infections were observed. There were no significant differences between AO type A and type B fractures in union rate or alignment parameters. CONCLUSIONS: Combined fluoroscopic–endoscopic assistance enables objective intraoperative evaluation of humeral rotational alignment during MIPO without compromising soft-tissue preservation. This technique provides reliable reduction quality and consistent healing outcomes in AO type A and B humeral shaft fractures, representing a practical refinement of standard MIPO principles.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
- Bone and Joint Research Center, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
- Department of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan. james770516@hotmail.com.
- Bone and Joint Research Center, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan. james770516@hotmail.com.
Zitieren
APA
Liu, C. H., Tsai, P. J., Chen, I. J., Lai, P. J., & Lai, C. Y. (2026). Intraoperative evaluation of rotational alignment in minimally invasive plate osteosynthesis for humeral shaft fractures using combined fluoroscopic and endoscopic assistance: surgical technique, clinical outcomes, and literature review. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-06170-7
Vancouver
Liu CH, Tsai PJ, Chen IJ, Lai PJ, Lai CY. Intraoperative evaluation of rotational alignment in minimally invasive plate osteosynthesis for humeral shaft fractures using combined fluoroscopic and endoscopic assistance: surgical technique, clinical outcomes, and literature review. Archives of Orthopaedic and Trauma Surgery. 2026. doi:10.1007/s00402-025-06170-7
BibTeX
@article{Liu2026,
author = {Liu, Chang-Heng and Tsai, Ping-Jui and Chen, I-Jung and Lai, Po-Ju and Lai, Chih-Yang},
title = {Intraoperative evaluation of rotational alignment in minimally invasive plate osteosynthesis for humeral shaft fractures using combined fluoroscopic and endoscopic assistance: surgical technique, clinical outcomes, and literature review},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2026},
doi = {10.1007/s00402-025-06170-7}
}
EUVIMED