Total wrist arthroplasty revisited: survival, function, and patient-reported outcomes of BIAX and universal II prostheses over 15 years
Archives of Orthopaedic and Trauma Surgery · 2025
DOI: 10.1007/s00402-025-06005-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Leonhard Mandl und 3 weiteren Autor:innen. Beteiligte Einrichtung: Universitätsklinikum Erlangen, Erlangen, Germany. Hauptthemen laut MEDLINE: Joint Prosthesis, Wrist Joint, Arthritis, Rheumatoid, Osteoarthritis. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Erlangen.
Abstract (Originalsprache)
Background
In the management of degenerative osteoarthritis and rheumatoid arthritis of the wrist, surgical intervention remains an important treatment option when conservative approaches such as medication, physiotherapy, and assistive devices prove insufficient. Despite decades of development, no single wrist prosthesis has yet emerged as the definitive standard in total wrist arthroplasty. To address this gap, the German Society for Hand Surgery established the Total Endoprosthesis (TEP) Register in 2004 to systematically collect and evaluate long-term clinical outcomes. The present prospective single-centre study analyses and presents the long-term results of patients enrolled in the TEP register, offering valuable insights into the performance and durability of wrist prostheses in a real-world clinical setting. Patients/materials/methods Between 2000 and 2011, a total of 29 total endoprostheses were implanted in 25 patients in a single centre study due to severe degenerative changes in the wrist. Of these, 22 had rheumatoid arthritis and 3 degenerative osteoarthritis. The prosthesis models BIAX ( N = 13) and Universal II ( N = 16) were implanted. The present study describes the mean outcome after a mean observation period of 13.8 (1.7–21.4) years for the BIAX prosthesis and 10.5 years (0.2–16.4) for the Universal II prosthesis.
Results
The probability of survival after 15 years is 60% for the BIAX prosthesis and 41% for the Universal II prosthesis. After 21 years, results are only available for the BIAX prosthesis with a value of 60%. The BIAX prosthesis showed a lower complication rate. Subjectively, 15 years postoperatively, the BIAX prosthesis showed a lower mean value in the QuickDASH score (BIAX 33.8%, Universal II 50.3%), lower results in the visual analogue pain scale under stress (BIAX: 1 point; Universal II: 3 points) with higher patient satisfaction (BIAX: 86%; Universal II: 78%).
Conclusion
In conclusion, our observations show that the BIAX prosthesis is superior to the Universal II prosthesis 15 years after surgery in terms of survival probability, complication rate and better results in satisfaction, the visual analogue pain scale and the QuickDASH score.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universitätsklinikum Erlangen, Erlangen, Germany.
- Medical Centre Demir, Nuernberg Germany, Germany.
- Universitätsklinikum Erlangen, Erlangen, Germany. demir@mvz-demir.de.
- Medical Centre Demir, Nuernberg Germany, Germany. demir@mvz-demir.de.
Förderung
- Universitätsklinikum Erlangen
Zitieren
APA
Mandl, L., Gruber, A., Horch, R. E., & Demir, R. (2025). Total wrist arthroplasty revisited: survival, function, and patient-reported outcomes of BIAX and universal II prostheses over 15 years. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-06005-5
Vancouver
Mandl L, Gruber A, Horch RE, Demir R. Total wrist arthroplasty revisited: survival, function, and patient-reported outcomes of BIAX and universal II prostheses over 15 years. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-06005-5
BibTeX
@article{Mandl2025,
author = {Mandl, Leonhard and Gruber, Alfred and Horch, Raymund E and Demir, Resit},
title = {Total wrist arthroplasty revisited: survival, function, and patient-reported outcomes of BIAX and universal II prostheses over 15 years},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2025},
doi = {10.1007/s00402-025-06005-5}
}
EUVIMED