A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty
Archives of Orthopaedic and Trauma Surgery · 2025
DOI: 10.1007/s00402-025-05828-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Kazuhiko Sonoda und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Iizuka Hospital, 3-83 Yoshiomachi, Iizuka, 820-8505, Japan. skazuhik@gmail.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Acetabulum. Die Arbeit nennt 30 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: We developed a fluoroscopic templating technique for accurate cup placement based on the acetabular morphology of individual patients during supine position total hip arthroplasty (THA) to reduce the risk of dislocation. This study aimed to evaluate cup positioning accuracy with and without this technique. MATERIALS AND METHODS: We evaluated 75 consecutive hips of 70 patients undergoing cementless anterolateral supine THA. The target angle for radiographic inclination (RI) and radiographic anteversion (RA) were set using a computed tomography (CT)-based functional pelvic plane. In 25 hips, we implanted the cup using a mechanical alignment guide (C-group). A fluoroscopic templating technique was used in 50 hips (FT-group), and a reference line based on the acetabular morphology was preoperatively set in each patient for the RI guide. A reference diagram was made for the RA guide. Postoperative CT scans were used to compare cup positioning accuracy between groups. RESULTS: The absolute values of the error from the target angle were 3.2 ± 2.0° (RI) and 6.5 ± 3.8° (RA) in the C-group, and 1.5 ± 1.2° (RI) and 2.6 ± 1.9° (RA) in the FT-group. The errors of both RI and RA were significantly smaller in the FT-group than in the C-group. The rates of cases within ± 5° of the target angles for both RI and RA were 48% (C-group) and 92% (FT-group). The mean fluoroscopic times were 32.2 s (C-group) and 17.4 s (FT-group). CONCLUSION: Our simple patient-specific technique achieved accurate cup positioning; this may reduce the risk of dislocation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Iizuka Hospital, 3-83 Yoshiomachi, Iizuka, 820-8505, Japan. skazuhik@gmail.com.
- Department of Orthopaedic Surgery, Iizuka Hospital, 3-83 Yoshiomachi, Iizuka, 820-8505, Japan.
Zitieren
APA
Sonoda, K., Kubo, Y., & Hara, T. (2025). A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-05828-6
Vancouver
Sonoda K, Kubo Y, Hara T. A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-05828-6
BibTeX
@article{Sonoda2025,
author = {Sonoda, Kazuhiko and Kubo, Yusuke and Hara, Toshihiko},
title = {A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2025},
doi = {10.1007/s00402-025-05828-6}
}
EUVIMED