EUVIMEDEUVIMED entdecken
Crossref

Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position

Masanori Okamoto, Yasuhiko Takegami, Yusuke Osawa, Shinya Tanaka, Tatsuya Nobori, Shiro Imagama

Archives of Orthopaedic and Trauma Surgery · 2024

DOI: 10.1007/s00402-024-05571-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Masanori Okamoto und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Yokkaichi Municipal Hospital, 11 2-2-37, Shibata, Yokkaichi-shi, Mie, 510-8567, Japan. masaokamotoo@yahoo.co.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Acetabulum, Surgical Navigation Systems, Accelerometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Total hip arthroplasty (THA) using a portable navigation system (PNS) incurs costs per procedure. However, it does not require a large console. This study aimed to compare the accuracy of acetabular cup placement using a pelvic alignment guide (PAG) attached to the pelvis and an accelerometer-based PNS in THA performed in the lateral decubitus position. METHODS: We retrospectively analyzed 100 hips that underwent primary THA in the lateral decubitus position between July 2018 and January 2021. The PAG was used in 50 hips, whereas the PNS was used in the other 50. Cup placement accuracy was measured using postoperative computed tomography scans, comparing errors in inclination and anteversion angles. The surgical time, blood loss, and complications were recorded. The follow-up period was at least 2 years in all cases. RESULTS: The mean absolute error of the inclination angle was similar between the groups (the PAG group: 3.7° ± 2.3° [range, 0.0-9.0]; the PNS group: 3.7° ± 2.3° [range, 0.2-10.5], p = 0.705). The mean absolute error of the anteversion angle was significantly smaller in the PAG group than in the PNS group (3.0° ± 2.4° [range, 0.0-9.7] vs. 6.5° ± 4.8° [range, 0.3-17.3], p < 0.001). The PAG group had a higher proportion of hips within 5° and 10° of the target angle (64 vs. 42%, P = 0.028, and 100 vs. 74%, p < 0.001, respectively). The PNS group had six hips with anteversion errors of 15° or more. Surgical time and blood loss were lower in the PAG group. The PNS group had one dislocation, whereas the PAG group did not. CONCLUSION: The accelerometer-based PNS did not demonstrate superior cup alignment accuracy compared to the PAG in THA performed in the lateral decubitus position. This finding informs surgeons that computer-assisted surgery is not necessarily superior to conventional THA using a PAG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipAcetabulumSurgical Navigation SystemsAccelerometryHumansFemaleMaleRetrospective StudiesAgedMiddle AgedPatient PositioningSurgery, Computer-AssistedHip ProsthesisAged, 80 and overTomography, X-Ray ComputedAdult

Stichwörter der Autor:innen

Alignment guideComputer-assisted surgeryHipPortable navigation systemsTotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Yokkaichi Municipal Hospital, 11 2-2-37, Shibata, Yokkaichi-shi, Mie, 510-8567, Japan. masaokamotoo@yahoo.co.jp.
  • Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya-shi, 466-8550, Japan.
  • Department of Orthopaedic Surgery, Yokkaichi Municipal Hospital, 11 2-2-37, Shibata, Yokkaichi-shi, Mie, 510-8567, Japan.

Zitieren

APA

Okamoto, M., Takegami, Y., Osawa, Y., Tanaka, S., Nobori, T., & Imagama, S. (2024). Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05571-4

Vancouver

Okamoto M, Takegami Y, Osawa Y, Tanaka S, Nobori T, Imagama S. Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05571-4

BibTeX
@article{Okamoto2024,
  author = {Okamoto, Masanori and Takegami, Yasuhiko and Osawa, Yusuke and Tanaka, Shinya and Nobori, Tatsuya and Imagama, Shiro},
  title = {Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2024},
  doi = {10.1007/s00402-024-05571-4}
}
Kostenlos starten →