EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Learning curve comparison between switching approach and switching implant in cementless short stem total hip arthroplasty

Christian Stadler, Jonas Sebastian Bolm, Clemens Schopper, Bernhard Schauer, Matthias Holzbauer, Tobias Gotterbarm, Matthias Luger

Archives of Orthopaedic and Trauma Surgery · 2024

DOI: 10.1007/s00402-024-05518-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Christian Stadler und 6 weiteren Autor:innen. Beteiligte Einrichtung: Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria. Christian.Stadler@kepleruniklinikum.at. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Learning Curve, Hip Prosthesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Johannes Kepler University Linz.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Implementing new approaches or new implants is always related with a certain learning curve in total hip arthroplasty (THA). Currently, many surgeons are switching to minimally invasive approaches combined with short stems for performing THA. Therefore, we aimed to asses and compare the learning curve of switching from an anterolateral Watson Jones approach (ALA) to a direct anterior approach (DAA) with the learning curve of switching from a neck-resecting to a partially neck-sparing short stem in cementless THA. Materials and methods The first 150 consecutive THA performed through a DAA (Group A) and the first 150 consecutive THA using a partially neck-sparing short stem (Group B) performed by a single surgeon were evaluated within this retrospective cohort study. All cases were screened for surgery related adverse events (AE). Furthermore, the operative time of each surgery was evaluated and the learning curve assessed performing a cumulative sum (CUSUM) analysis.

Results

Overall, significantly more AE occurred in Group A compared to Group B (18.0% vs. 10.0%; p = 0.046). The sub-analysis of the AE revealed higher rates of periprosthetic joint infections (2.7% vs. 0.7%; p = 0.176), periprosthetic fractures (4.0% vs. 2.0%; p = 0.310) and overall revisions (4.7% vs. 1.3% p = 0.091) within Group A without statistical significance. The CUSUM analysis revealed a consistent reduction of operative time after 97 cases in Group A and 79 cases in Group B.

Conclusion

A significantly higher overall rate of AE was detected while switching approach compared to switching implant for performing THA. However, according to the results of this study, surgeons should be aware of the learning curve of the adoption to a new implant with different fixation philosophy as well.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipLearning CurveHip ProsthesisHumansRetrospective StudiesFemaleMaleMiddle AgedAgedPostoperative ComplicationsProsthesis DesignOperative TimeAdult

Stichwörter der Autor:innen

Cementless short stemDirect anterior approachLearning curveTotal hip arthroplasty

Autor:innen und Institutionen

  • Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria. Christian.Stadler@kepleruniklinikum.at.
  • Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria. Christian.Stadler@kepleruniklinikum.at.
  • Johannes Kepler University Linz, Altenberger Strasse 96, Linz, 4040, Austria.
  • Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstraße 9, Linz, 4020, Austria.

Förderung

  • Johannes Kepler University Linz

Zitieren

APA

Stadler, C., Bolm, J. S., Schopper, C., Schauer, B., Holzbauer, M., Gotterbarm, T., & Luger, M. (2024). Learning curve comparison between switching approach and switching implant in cementless short stem total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05518-9

Vancouver

Stadler C, Bolm JS, Schopper C, Schauer B, Holzbauer M, Gotterbarm T, et al. Learning curve comparison between switching approach and switching implant in cementless short stem total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05518-9

BibTeX
@article{Stadler2024,
  author = {Stadler, Christian and Bolm, Jonas Sebastian and Schopper, Clemens and Schauer, Bernhard and Holzbauer, Matthias and Gotterbarm, Tobias and Luger, Matthias},
  title = {Learning curve comparison between switching approach and switching implant in cementless short stem total hip arthroplasty},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2024},
  doi = {10.1007/s00402-024-05518-9}
}
Kostenlos starten →