EUVIMEDEUVIMED entdecken
Crossref

Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur

Yoshihisa Ohashi, Kensuke Fukushima, Maho Tsuchiya, Hiroki Saito, Kentaro Uchida, Katsufumi Uchiyama, Naonobu Takahira, Masashi Takaso

Archives of Orthopaedic and Trauma Surgery · 2024

DOI: 10.1007/s00402-024-05430-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Yoshihisa Ohashi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Bone Density, Durapatite, Hip Prosthesis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study aimed to compare the impact of different broach surface designs on post-operative clinical outcomes, bone reactions and changes in bone mineral density (BMD) in patients who underwent total hip arthroplasty (THA) using a fully hydroxyapatite coated and double tapered stem with either compaction shape (COM) or hybrid shape (HYB) broaches. MATERIALS AND METHODS: A retrospective analysis was conducted on 76 patients (100 hips) who underwent primary THA using the Avenir complete stem®. Patients were divided into two groups: the COM broach group (50 hips) and HYB broach group (50 hips). We evaluated clinical outcomes using the Japanese Orthopaedic Association hip scores one month before the surgery, and 12 and 24 months after the surgery. Radiographic findings, including stem alignment angles, radiolucent lines, spot welds, and cortical hypertrophy, were assessed. BMD around the stem in Gruen zones 1-7 was evaluated using dual-energy X-ray absorptiometry (DEXA) at 7 days, 12, and 24 months post-operatively. The Dorr classification was used to assess femoral morphology. RESULTS: There were no significant differences in clinical outcomes, radiographic findings, or BMD changes between the COM and HYB broach groups in the overall patient cohort. However, in Dorr type A femurs, the COM broach group demonstrated superior BMD superior preservation in zones 1 and 7 after 12 months and in zones 1, 6 and 7 after 24 months. Additionally, in Dorr type B femurs, significant BMD preservation was observed in zone 3 at 24 months in the COM broach group. CONCLUSIONS: This study suggests that the broach surface design of fully hydroxyapatite coated stems may influence periprosthetic BMD changes, especially in Dorr type A and B femurs. Surgeons should consider broach selection based on patient-specific femoral morphology to optimize BMD preservation in THA procedures using fully hydroxyapatite coated stems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipBone DensityDurapatiteHip ProsthesisProsthesis DesignHumansMaleFemaleRetrospective StudiesMiddle AgedAgedFemurAbsorptiometry, PhotonAdult

Stichwörter der Autor:innen

Bone mineral densityBroach surface designDORR classificationFemoral morphologyFully hydroxyapatite-coated stemTotal hip arthroplasty

Substanzen

Durapatite

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
  • Department of Orthopedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan. kenfu@r4.dion.ne.jp.
  • Department of Patient Safety and Healthcare Administration, Kitasato University School of Medicine, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.
  • Department of Rehabilitation, Kitasato University School of Allied Health Sciences, 1-15-1 Minami-Ku, Kitasato, Sagamihara City, Kanagawa, 252-0374, Japan.

Zitieren

APA

Ohashi, Y., Fukushima, K., Tsuchiya, M., Saito, H., Uchida, K., Uchiyama, K., Takahira, N., & Takaso, M. (2024). Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05430-2

Vancouver

Ohashi Y, Fukushima K, Tsuchiya M, Saito H, Uchida K, Uchiyama K, et al. Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05430-2

BibTeX
@article{Ohashi2024,
  author = {Ohashi, Yoshihisa and Fukushima, Kensuke and Tsuchiya, Maho and Saito, Hiroki and Uchida, Kentaro and Uchiyama, Katsufumi and Takahira, Naonobu and Takaso, Masashi},
  title = {Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2024},
  doi = {10.1007/s00402-024-05430-2}
}
Kostenlos starten →