The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types
Archives of Orthopaedic and Trauma Surgery · 2024
DOI: 10.1007/s00402-024-05361-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Kun-Han Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Postoperative Complications, Prosthesis Design. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The choice between a cementless taper wedge stem and a fit-and-fill stem in total Hip arthroplasty (THA) for various proximal femoral morphological types has not been thoroughly evaluated. This study aimed to compare the risk of stem-related complications between these two stem types in Dorr type A, B, and C femurs. MATERIALS AND METHODS: From January 2015 through April 2021, we retrospectively reviewed 1995 cementless THA procedures. We stratified all procedures into three groups: Dorr type A (N = 360, 18.0%), B (N = 1489, 74.7%) and C (N = 146, 7.3%). The primary outcome domain was stem-related complications, including stem subsidence ≥ 3 mm, intraoperative fracture, periprosthetic fracture and aseptic stem loosening. We performed multivariate regression analysis to compare the risk of stem-related complication between the two stem types. Other factors included age, sex, body mass index, diagnosis, age-adjusted Charlson comorbidity index, stem alignment and canal fill ratio. RESULTS: The incidence of stem-related complications in the taper wedge and fit-and-fill stem groups was 4.4% (N = 15) and 6.5% (N = 107), respectively. Fit-and-fill stems showed an increased risk of stem-related complications (aOR: 9.903, 95% CI: 1.567-62.597) only in Dorr type C femurs. No significant difference in risk was observed in Dorr type A and B femurs. Furthermore, the canal fill ratio at the lesser trochanter, 2 cm and 7 cm below the lesser trochanter, did not exhibit an association with stem-related complications in any Dorr type. CONCLUSIONS: Concerning the risk of stem-related complications, the taper wedge stem was a better choice in Dorr type C femurs. However, there was no difference in risk between the taper wedge stem and fit-and-fill stem in Dorr type A and B femurs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan.
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei, 11217, Taiwan. swtsai.vghtpe@gmail.com.
- Department of Orthopaedics, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan. swtsai.vghtpe@gmail.com.
Zitieren
APA
Lee, K. H., Hung, Y. T., Chang, C. Y., Wang, J. C., Tsai, S. W., Chen, C. F., Wu, P. K., & Chen, W. M. (2024). The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05361-y
Vancouver
Lee KH, Hung YT, Chang CY, Wang JC, Tsai SW, Chen CF, et al. The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05361-y
BibTeX
@article{Lee2024,
author = {Lee, Kun-Han and Hung, Yueh-Ting and Chang, Cheng-Yang and Wang, Jui-Chien and Tsai, Shang-Wen and Chen, Cheng-Fong and Wu, Po-Kuei and Chen, Wei-Ming},
title = {The cementless taper wedge vs. fit-and-fill stem in primary total hip arthroplasty: risk of stem-related complication differs across Dorr types},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2024},
doi = {10.1007/s00402-024-05361-y}
}
EUVIMED