Retrospective study comparing the accuracies of handheld infrared stereo camera and augmented reality-based navigation systems for total hip arthroplasty

Shinya Tanaka, Yasuhiko Takegami, Yusuke Osawa, Masanori Okamoto, Shiro Imagama

Archives of Orthopaedic and Trauma Surgery · 2024

DOI: 10.1007/s00402-024-05330-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Shinya Tanaka und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya-Shi, 466-8550, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Augmented Reality, Surgical Navigation Systems, Surgery, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The use of portable navigation systems (PNS) in total hip arthroplasty (THA) has become increasingly prevalent, with second-generation PNS (sPNS) demonstrating superior accuracy in the lateral decubitus position compared to first-generation PNS. However, few studies have compared different types of sPNS. This study retrospectively compares the accuracy and clinical outcomes of two different types of sPNS instruments in patients undergoing THA. METHODS: A total of 158 eligible patients who underwent THA at a single institution between 2019 and 2022 were enrolled in the study, including 89 who used an accelerometer-based PNS with handheld infrared stereo cameras in the Naviswiss group (group N) and 69 who used an augmented reality (AR)-based PNS in the AR-Hip group (group A). Accuracy error, navigation error, clinical outcomes, and preparation time were compared between the two groups. RESULTS: Accuracy errors for Inclination were comparable between group N (3.5° ± 3.0°) and group A (3.5° ± 3.1°) (p = 0.92). Accuracy errors for anteversion were comparable between group N (4.1° ± 3.1°) and group A (4.5° ± 4.0°) (p = 0.57). The navigation errors for inclination (group N: 2.9° ± 2.7°, group A: 3.0° ± 3.2°) and anteversion (group N: 4.3° ± 3.5°, group A: 4.3° ± 4.1°) were comparable between the groups (p = 0.86 and 0.94, respectively). The preparation time was shorter in group A than in group N (p = 0.036). There were no significant differences in operative time (p = 0.255), intraoperative blood loss (p = 0.387), or complications (p = 0.248) between the two groups. CONCLUSION: An Accelerometer-based PNS using handheld infrared stereo cameras and AR-based PNS provide similar accuracy during THA in the lateral decubitus position, with a mean error of 3°-4° for both inclination and anteversion, though the AR-based PNS required a shorter preparation time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipAugmented RealitySurgical Navigation SystemsSurgery, Computer-AssistedHumansRetrospective StudiesFemaleMaleAgedMiddle AgedInfrared Rays

Stichwörter der Autor:innen

Acetabular cup orientationHip OsteoarthritisPortable imageless navigation systemSurgical Navigation SystemsTotal hip arthroplasty

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya-Shi, 466-8550, Japan.
  • Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-Cho, Showa-Ku, Nagoya-Shi, 466-8550, Japan. takegami@med.nagoya-u.ac.jp.
  • Yokkaichi Municipal Hospital, 2-2-37, Shibata, Yokkaichi-Shi, Mie, 510-8567, Japan.

Zitieren

APA

Tanaka, S., Takegami, Y., Osawa, Y., Okamoto, M., & Imagama, S. (2024). Retrospective study comparing the accuracies of handheld infrared stereo camera and augmented reality-based navigation systems for total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05330-5

Vancouver

Tanaka S, Takegami Y, Osawa Y, Okamoto M, Imagama S. Retrospective study comparing the accuracies of handheld infrared stereo camera and augmented reality-based navigation systems for total hip arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05330-5

BibTeX
@article{Tanaka2024,
  author = {Tanaka, Shinya and Takegami, Yasuhiko and Osawa, Yusuke and Okamoto, Masanori and Imagama, Shiro},
  title = {Retrospective study comparing the accuracies of handheld infrared stereo camera and augmented reality-based navigation systems for total hip arthroplasty},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2024},
  doi = {10.1007/s00402-024-05330-5}
}
Kostenlos starten →