EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Aseptic midterm survival rates between different cemented tibial stem designs in hinged total knee arthroplasty: a 6-year evaluation from the German Arthroplasty Registry

Alexander Maslaris, Alexander Grimberg, Oliver Melsheimer, Elefterios Tsiridis, Georg Matziolis

Archives of Orthopaedic and Trauma Surgery · 2024

DOI: 10.1007/s00402-024-05273-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Alexander Maslaris und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Department at Campus Eisenberg, University Hospital Jena, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany. alexander_maslaris@hotmai…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Registries, Knee Prosthesis, Prosthesis Failure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Jena.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates.

Methods

Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan–Meier curve and compared between groups via Log-Rank-Tests.

Results

3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7).

Conclusion

There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRegistriesKnee ProsthesisProsthesis FailureProsthesis DesignReoperationHumansGermanyMaleAgedFemaleTibiaMiddle AgedBone Cements

Stichwörter der Autor:innen

Aseptic survival rateCemented revision total knee arthroplastyCemented stemsConical stemsCumulative aseptic revision rateStem conicityStem designStem diameterStem lengthStem offsetTibial stems

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Orthopaedic Department at Campus Eisenberg, University Hospital Jena, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany. alexander_maslaris@hotmail.com.
  • German Arthroplasty Registry gGmbH (EPRD), EPRD Deutsche Endoprothesenregister gGmbH, Straße des 17. Juni 106-108 (Eingang Bachstraße), 10623, Berlin, Germany.
  • Academic Orthopaedic Department, Papageorgiou General Hospital, Aristotle University Medical School, Thessaloníki, Greece.
  • Orthopaedic Department at Campus Eisenberg, University Hospital Jena, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany.

Förderung

  • Universitätsklinikum Jena

Zitieren

APA

Maslaris, A., Grimberg, A., Melsheimer, O., Tsiridis, E., & Matziolis, G. (2024). Aseptic midterm survival rates between different cemented tibial stem designs in hinged total knee arthroplasty: a 6-year evaluation from the German Arthroplasty Registry. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05273-x

Vancouver

Maslaris A, Grimberg A, Melsheimer O, Tsiridis E, Matziolis G. Aseptic midterm survival rates between different cemented tibial stem designs in hinged total knee arthroplasty: a 6-year evaluation from the German Arthroplasty Registry. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05273-x

BibTeX
@article{Maslaris2024,
  author = {Maslaris, Alexander and Grimberg, Alexander and Melsheimer, Oliver and Tsiridis, Elefterios and Matziolis, Georg},
  title = {Aseptic midterm survival rates between different cemented tibial stem designs in hinged total knee arthroplasty: a 6-year evaluation from the German Arthroplasty Registry},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2024},
  doi = {10.1007/s00402-024-05273-x}
}
Kostenlos starten →