Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2023. Verfasst von Peter Bo Jørgensen und 4 weiteren Autor:innen. Beteiligte Einrichtung: AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark. pbjr@clin.a…. Hauptthemen laut MEDLINE: Hip Prosthesis, Hip Dislocation, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Mobilisation
Abstract (Originalsprache)
INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark. pbjr@clin.au.dk.
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands.
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark.
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark.
Zitieren
APA
Jørgensen, P. B., Kaptein, B. L., Søballe, K., Jakobsen, S. S., & Stilling, M. (2023). Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-023-04774-5
Vancouver
Jørgensen PB, Kaptein BL, Søballe K, Jakobsen SS, Stilling M. Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct. Archives of Orthopaedic and Trauma Surgery. 2023. doi:10.1007/s00402-023-04774-5
BibTeX
@article{Jrgensen2023,
author = {Jørgensen, Peter Bo and Kaptein, Bart L and Søballe, Kjeld and Jakobsen, Stig S and Stilling, Maiken},
title = {Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2023},
doi = {10.1007/s00402-023-04774-5}
}
EUVIMED