Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty
Archives of Orthopaedic and Trauma Surgery · 2023
DOI: 10.1007/s00402-023-04772-7 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2023. Verfasst von Felix Riechelmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. felix.riechelmann@i-med.ac.a…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Arthroplasty, Replacement, Hip. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Innsbruck and Medical University of Innsbruck.
Abstract (Originalsprache)
Purpose
To analyze the match between preoperatively determined implant size (2D templating) and intraoperatively used implant size in total knee arthroplasty (TKA). Also examined were the factors that might influence templating accuracy (gender, surgeon experience, obesity, etc.). Materials and methods The study was retrospective and conducted in a specialized ENDOCERT arthroplasty center. Digital templating was done with the MediCAD software. If the planned and implanted TKA components (both femur and tibia) were the same size, the match was classified “exact.” A deviation of ± one size (at the femur or tibia or both) was classified “accurate.” A deviation of ± two or more sizes (at the femur or tibia or both) was classified “inaccurate.” Obesity, gender, implant type and surgeon experience were investigated for potential influence on templating accuracy. Chi-square tests and Cohen’s weighted kappa test were used for statistical analysis.
Results
A total of 482 cases [33.6% male, 66.4% female, age 69 ± 11, body mass index (BMI) 30.3 ± 5.8] were included. When the femur and tibia were taken together, exact size match was observed in 34% (95% CI 29.9–38.3%) of cases, accurate size match in 57.5% (95% CI 53–61.8%) and inaccurate size match in 8.5% (95% CI 6.3–11.2%). Inaccurate size match prolonged operative time ( p = 0.028). Regarding the factors potentially influencing templating accuracy, only gender had a significant influence, with templating being more accurate in men ( p = 0.004). BMI had no influence on accuracy ( p = 0.87). No effect on accuracy was observed for implant type and surgeon experience.
Conclusions
The accuracy of 2D size templating in TKA is low, even in a specialized ENDOCERT arthroplasty center. The study findings challenge the usefulness of preoperative 2D size templating and highlight the importance of more reliable templating methods. Level of evidence Level III (retrospective observational study).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria. felix.riechelmann@i-med.ac.at.
- Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstrasse 35, 6020, Innsbruck, Austria.
- Ortoklinik, Ankara, Turkey.
- Department of Orthopaedics and Traumatology, Halic University, Istanbul, Turkey.
- University Hospital Krems, Krems, Austria.
Förderung
- University of Innsbruck and Medical University of Innsbruck
Zitieren
APA
Riechelmann, F., Lettner, H., Mayr, R., Tandogan, R., Dammerer, D., & Liebensteiner, M. (2023). Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-023-04772-7
Vancouver
Riechelmann F, Lettner H, Mayr R, Tandogan R, Dammerer D, Liebensteiner M. Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2023. doi:10.1007/s00402-023-04772-7
BibTeX
@article{Riechelmann2023,
author = {Riechelmann, Felix and Lettner, H and Mayr, R and Tandogan, R and Dammerer, D and Liebensteiner, M},
title = {Imprecise prediction of implant sizes with preoperative 2D digital templating in total knee arthroplasty},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2023},
doi = {10.1007/s00402-023-04772-7}
}
EUVIMED