EUVIMEDEUVIMED entdecken
Crossref

Complications following arthroscopic-assisted coracoclavicular stabilization in patients with unstable lateral clavicle fractures

Alexander Pieringer, JoEllen Welter, Janic Fischer, Florian Hess

Archives of Orthopaedic and Trauma Surgery · 2023

DOI: 10.1007/s00402-023-04769-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2023. Verfasst von Alexander Pieringer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shoulder and Elbow Surgery, Schulthess Klinik, Zurich, Switzerland. Hauptthemen laut MEDLINE: Fractures, Bone, Acromioclavicular Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Lateral clavicle fractures are unstable and prone to nonunions, which is why they are often treated surgically rather than conservatively. Despite the variety of surgical techniques found in the literature, the best method for treating this rare fracture type has not yet been determined. Our case series aimed to describe a coracoclavicular (CC) reconstruction technique and to assess complications and patient outcomes 1 year postoperatively. METHODS: Nineteen patients who underwent surgery for an unstable lateral clavicle fracture (IIB, IIC, IID) with a suture button device (Dog Bone, Arthrex, Inc., Naples, FL, USA) were available for clinical and radiological follow-up. The assessments included the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) score, the Constant Score (CS), the Subjective Shoulder Value (SSV), as well as the ipsilateral and contralateral coracoclavicular distance. RESULTS: The median age was 50 years (IQR 28-59), 13 (68.4%) were male and the delay to surgery was 5 days (IQR 2-9). The median clinical scores were 100 (ASES), 91 (CS), and 95 (SSV). The CC distance improved postoperatively (p = 0.003). However, nonunion occurred in 3 (15.8%) patients, 5 (26.3%) had other complications, and 5 (26.3%) needed revision surgery (4 plate removals and 1 pseudoarthrosis). The overall complication rate was 36.8%. CONCLUSION: Restoring the CC ligaments alone could not reliably achieve fracture stability, with more than one-third of cases in this series experiencing major complications. Given the high revision and nonunion rates, we do not recommend this type of surgical technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractures, BoneAcromioclavicular JointMaleAnimalsDogsFemaleFracture Fixation, InternalClavicleLigaments, ArticularBone PlatesTreatment Outcome

Stichwörter der Autor:innen

Cho classificationCoracoclavicular reconstructionLateral clavicle fractureNonunion

Autor:innen und Institutionen

  • Shoulder and Elbow Surgery, Schulthess Klinik, Zurich, Switzerland.
  • Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland.
  • Department of Orthopedic Surgery and Traumatology, Cantonal Hospital Frauenfeld, Pfaffenholzstrasse 4, 8501, Frauenfeld, Switzerland. florian.hess@stgag.ch.

Zitieren

APA

Pieringer, A., Welter, J., Fischer, J., & Hess, F. (2023). Complications following arthroscopic-assisted coracoclavicular stabilization in patients with unstable lateral clavicle fractures. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-023-04769-2

Vancouver

Pieringer A, Welter J, Fischer J, Hess F. Complications following arthroscopic-assisted coracoclavicular stabilization in patients with unstable lateral clavicle fractures. Archives of Orthopaedic and Trauma Surgery. 2023. doi:10.1007/s00402-023-04769-2

BibTeX
@article{Pieringer2023,
  author = {Pieringer, Alexander and Welter, JoEllen and Fischer, Janic and Hess, Florian},
  title = {Complications following arthroscopic-assisted coracoclavicular stabilization in patients with unstable lateral clavicle fractures},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2023},
  doi = {10.1007/s00402-023-04769-2}
}
Kostenlos starten →