Functional consequences of diminished myocardial oxygen delivery per beat in experimental heart failure
Basic Research in Cardiology · 2026
DOI: 10.1007/s00395-026-01186-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Basic Research in Cardiology, 2026. Verfasst von Salman I Essajee und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology and Anatomy, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, TX, 76107, USA. Hauptthemen laut MEDLINE: Heart Failure, Coronary Circulation, Oxygen Consumption, Myocardium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, National Heart, Lung, and Blood Institute.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
This investigation was designed to test the hypothesis that heart failure (HF) attenuates coronary vasodilation and autoregulation and that deficits in contractile function are proportionally related to reductions in the volume of myocardial perfusion and oxygen delivered per beat. Utilizing a pacing-induced model of HF in Ossabaw swine, we determined that chronic pacing at 180 beats/min for ~ 4 weeks significantly reduced baseline coronary flow by ~ 45% ( P = 0.01), lowered myocardial oxygen consumption (MVO₂) ( P = 0.07) and systolic wall thickening by ~ 30% ( P < 0.01), and increased left ventricular end-diastolic pressure ~ 160% ( P < 0.05). Coronary flow responses to Regadenoson (0.4 mg) and cardiac pacing (180 beats/min) were significantly attenuated in swine with pacing HF ( P ≤ 0.01). Control swine displayed relatively strong autoregulatory capability with coronary flow decreasing ~ 10% ( P = 0.26) as blood pressure was pharmacologically reduced from 120 to 60 mmHg. Alternatively, coronary flow decreased ~ 40% ( P = 0.01) over the same pressure range in pacing HF swine. Regional wall thickening and stroke volume declined once myocardial oxygen delivery fell below ~ 1.0 µL O₂/g/beat. These findings indicate that adaptations in the coronary microcirculation in pacing HF attenuate coronary metabolic and autoregulatory capacity and that subsequent functional deficits are related to reductions in the volume of myocardial perfusion and oxygen delivered per beat.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physiology and Anatomy, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, TX, 76107, USA.
- Section of Vascular Surgery, Department of Surgery, University of Michigan, Ann Arbor, MI, USA.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
- Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, MI, USA.
- Department of Physiology and Anatomy, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, TX, 76107, USA. johnathan.tune@unthealth.edu.
Förderung
- NHLBI NIH HHS
- National Heart, Lung, and Blood Institute
Zitieren
APA
Essajee, S. I., Eden, M. J., Sturgess, V. E., Dick, G. M., Tucker, S. M., Warne, C. M., Figueroa, C. A., Beard, D. A., & Tune, J. D. (2026). Functional consequences of diminished myocardial oxygen delivery per beat in experimental heart failure. Basic Research in Cardiology. https://doi.org/10.1007/s00395-026-01186-5
Vancouver
Essajee SI, Eden MJ, Sturgess VE, Dick GM, Tucker SM, Warne CM, et al. Functional consequences of diminished myocardial oxygen delivery per beat in experimental heart failure. Basic Research in Cardiology. 2026. doi:10.1007/s00395-026-01186-5
BibTeX
@article{Essajee2026,
author = {Essajee, Salman I and Eden, Matthew J and Sturgess, Victoria E and Dick, Gregory M and Tucker, Selina M and Warne, Cooper M and Figueroa, C Alberto and Beard, Daniel A and Tune, Johnathan D},
title = {Functional consequences of diminished myocardial oxygen delivery per beat in experimental heart failure},
journal = {Basic Research in Cardiology},
year = {2026},
doi = {10.1007/s00395-026-01186-5}
}
EUVIMED