EUVIMEDEUVIMED entdecken
Vergleichsstudie

Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification

Grigorios Korosoglou, Nadine Abanador-Kamper, Christian Tesche, Matthias Renker, Florian André, Loris Weichsel, Michaela Hell, Florian Bönner, Mareike Cramer, Sebastian Kelle, Jeanette Schulz-Menger, Wolfgang Fehske und 4 weitere

Clinical Research in Cardiology · 2026

DOI: 10.1007/s00392-025-02661-0 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Research in Cardiology, 2026. Verfasst von Grigorios Korosoglou und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Vascular Medicine and Pneumology, GRN Hospital Weinheim, Roentgenstr. 1, 69469, Weinheim, Germany. gkorosoglou@hotmail.com. Hauptthemen laut MEDLINE: Coronary Artery Disease, Coronary Angiography, Computed Tomography Angiography, Certification. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

AIM: To compare the reproducibility in reporting of coronary computed tomography angiography (CCTA) or cardiovascular magnetic resonance imaging (CMR) by certified readers for CCTA and CMR by the German Society of Cardiology (DGK) versus that by non-certified readers. METHODS: The study included 40 randomly selected CCTA and vasodilator stress CMR patient datasets. For CCTA, the degree of lumen narrowing, plaque composition, and high-risk plaque features were assessed. For CMR, wall motion and perfusion abnormalities and late gadolinium enhancement (LGE) were rated. All measures were conducted by segments and for individual patients. Intraclass correlation coefficients (ICC) were calculated to assess agreement between non-certified (n = 4) vs. DGK-certified readers (n = 4). RESULTS: ICC for assessment of luminal narrowing, plaque composition, and high-risk features were, respectively, 0.65 (95% confidence intervals [CI] 0.59-0.69), 0.64 (95%CI 0.45-0.80), and 0.45 (95%CI 0.22-0.66) for non-certified versus 0.78 (95%CI 0.74-0.81), 0.88 (95%CI 0.79-0.93), and 0.89 (95%CI 0.81-0.95) for DGK-certified readers (p < 0.001 for all). ICC for the assessment of wall motion, perfusion, and LGE were, respectively, 0.41 (95%CI 0.35-0.48), 0.27 (95%CI 0.18-0.38), and 0.48 (95%CI 0.41-0.54) for non-certified versus 0.71 (95%CI 0.67-0.75), 0.71 (95%CI 0.67-0.75) and 0.67 (95%CI 0.62-0.71) for DGK-certified readers (p < 0.001 for all). The agreement was excellent among DGK-certified readers for obstructive CAD (≥ 70% lumen narrowing) assessed by CCTA and high for abnormal perfusion and for LGE by CMR in a per-patient analysis (0.88; 95%CI 0.79-0.94 and 0.84; 95%CI 0.71-0.92), respectively. CONCLUSION: Substantially better CCTA and CMR reporting was observed for DGK-certified cardiologists, who achieved high agreement for diagnosing the presence or absence of obstructive CAD by CCTA and abnormal perfusion by CMR. Since important clinical decisions may be based on these readings, our data support quality-controlled education programs for advanced cardiac imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery DiseaseCoronary AngiographyComputed Tomography AngiographyCertificationCoronary VesselsMagnetic Resonance Imaging, CineHumansMaleFemaleMiddle AgedReproducibility of ResultsObserver VariationAged

Stichwörter der Autor:innen

Coronary artery diseaseIntraclass correlationLate gadolinium enhancementMyocardial perfusion imagingNon-calcified plaquePlaque quantification

Autor:innen und Institutionen

  • Department of Cardiology, Vascular Medicine and Pneumology, GRN Hospital Weinheim, Roentgenstr. 1, 69469, Weinheim, Germany. gkorosoglou@hotmail.com.
  • Cardiac Imaging Center Weinheim, Hector Foundations, Weinheim, Germany. gkorosoglou@hotmail.com.
  • Heart Center Wuppertal, Witten/Herdecke University, Wuppertal, Germany.
  • Department of Cardiology, Munich University Clinic, Ludwig-Maximilians-University, Munich, Germany.
  • Department of Cardiology, Campus Kerckhoff of the Justus Liebig University Giessen, Bad Nauheim, Germany.
  • German Centre for Cardiovascular Research (DZHK), Partner Site Rhein Main, Bad Nauheim, Germany.

Zitieren

APA

Korosoglou, G., Abanador-Kamper, N., Tesche, C., Renker, M., André, F., Weichsel, L., Hell, M., Bönner, F., Cramer, M., Kelle, S., Schulz-Menger, J., Fehske, W., Rolf, A., Frey, N., Thiele, H., & Baldus, S. (2026). Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification. Clinical Research in Cardiology. https://doi.org/10.1007/s00392-025-02661-0

Vancouver

Korosoglou G, Abanador-Kamper N, Tesche C, Renker M, André F, Weichsel L, et al. Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification. Clinical Research in Cardiology. 2026. doi:10.1007/s00392-025-02661-0

BibTeX
@article{Korosoglou2026,
  author = {Korosoglou, Grigorios and Abanador-Kamper, Nadine and Tesche, Christian and Renker, Matthias and André, Florian and Weichsel, Loris and Hell, Michaela and Bönner, Florian and Cramer, Mareike and Kelle, Sebastian and Schulz-Menger, Jeanette and Fehske, Wolfgang and Rolf, Andreas and Frey, Norbert and Thiele, Holger and Baldus, Stephan},
  title = {Observer variabilities for the diagnosis of coronary artery disease using anatomical and functional testing: the impact of certification},
  journal = {Clinical Research in Cardiology},
  year = {2026},
  doi = {10.1007/s00392-025-02661-0}
}
Kostenlos starten →