One-year outcome of robotical vs. manual percutaneous coronary intervention
Clinical Research in Cardiology · 2025-08 · 114 (8) · 1000-1007
DOI: 10.1007/s00392-024-02524-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Research in Cardiology, online erschienen am 21.08.2024. Verfasst von Constantin von Zur Mühlen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Angiology, Faculty of Medicine, Heart Center Freiburg University, University of Freiburg, Hugstetterstr. 55, 79106, Frei…. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Registries, Robotic Surgical Procedures, Coronary Artery Disease. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Freiburg.
Abstract (Originalsprache)
Background
Robotic-assisted percutaneous coronary intervention (R-PCI) is a promising technology for optimizing the treatment of patients with coronary heart disease. For a better understanding of the potential of R-PCI in clinical routine compared to conventional manual PCI (M-PCI) both initial treatment success of the index procedure and long-term outcome have to be analysed.
Methods
Prospective evaluation from the FRiK (DRKS00023868) registry of all R-PCI cases with the CorPath GRX Cardiology by Siemens Healthineers and Corindus in the Freiburg University Heart Center between 04/2022 and 03/2023. Index procedure success and safety, radiation dose of patients and personnel, and 1-year outcome will be reported. Findings will be compared to a prospective control group of M-PCI patients treated by the same team of interventionalists during the same observation period.
Results
Seventy patients received R-PCI and were included in the registry. PCI success rate was 100%, with 19% requiring manual assistance. No complications (MACE—major adverse cardiovascular events) occurred. Compared with 70 matched-pair M-PCI patients, there was a higher median procedural time (103 min vs. 67 min, p < 0.001) and fluoroscopy time (18 min vs. 15 min, p = 0.002), and more contrast volume was used (180 ml vs. 160 ml, p = 0.041) in R-PCI vs. M-PCI patients. However, there was no significant difference of the dose-area product (4062 vs. 3242 cGycm 2 , p = 0.361). One year after the intervention, there was no difference in mortality, rehospitalisation, unscheduled PCI or target vessel failure. Health-related quality of life evaluation 6 and 12 months after the index procedure (NYHA, CCS, SAQ7 and EQ-5D-5L) was similar in both groups.
Conclusion
R-PCI is feasible and safe. Compared to M-PCI, index procedure success rate is high, safety profile is favourable, and manual assistance was required in only few cases. At 1-year follow-up results for R-PCI vs. M-PCI considering mortality, rehospitalisation, morbidity and target vessel failure were equal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology and Angiology, Faculty of Medicine, Heart Center Freiburg University, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany.
- Max Grundig Klinik, Bühl, Germany.
- Interdisciplinary Medical Intensive Care, Faculty of Medicine, Medical Center, University of Freiburg, Freiburg, Germany.
- Heidelberg Institute of Global Health, University of Heidelberg, Heidelberg, Germany.
- Institute of Medical Biometry and Statistics, Faculty of Medicine, University Medical Center Freiburg, University of Freiburg, Freiburg, Germany.
- Department of Cardiology and Angiology, Faculty of Medicine, Heart Center Freiburg University, University of Freiburg, Hugstetterstr. 55, 79106, Freiburg, Germany. jonathan.rilinger@uniklinik-freiburg.de.
Förderung
- Universitätsklinikum Freiburg
Zitieren
APA
von Zur Mühlen, C., Jeuck, M., Heidt, T., Maulhardt, T., Hartikainen, T., Supady, A., Hilgendorf, I., Wolf, D., Kaier, K., Westermann, D., & Rilinger, J. (2025). One-year outcome of robotical vs. manual percutaneous coronary intervention. Clinical Research in Cardiology, 114(8), 1000-1007. https://doi.org/10.1007/s00392-024-02524-0
Vancouver
von Zur Mühlen C, Jeuck M, Heidt T, Maulhardt T, Hartikainen T, Supady A, et al. One-year outcome of robotical vs. manual percutaneous coronary intervention. Clinical Research in Cardiology. 2025;114(8):1000-1007. doi:10.1007/s00392-024-02524-0
BibTeX
@article{vonZurMhlen2025,
author = {von Zur Mühlen, Constantin and Jeuck, Marvin and Heidt, Timo and Maulhardt, Thomas and Hartikainen, Tau and Supady, Alexander and Hilgendorf, Ingo and Wolf, Dennis and Kaier, Klaus and Westermann, Dirk and Rilinger, Jonathan},
title = {One-year outcome of robotical vs. manual percutaneous coronary intervention},
journal = {Clinical Research in Cardiology},
year = {2025},
volume = {114},
number = {8},
pages = {1000--1007},
doi = {10.1007/s00392-024-02524-0}
}