Fractional flow reserve predicts major adverse cardiac events after coronary stent implantation
Zeitschrift f�r Kardiologie · 01.07.2002 · 91 · 132-136
DOI: 10.1007/s00392-002-1324-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Zeitschrift f�r Kardiologie, erschienen am 01.07.2002. Verfasst von Johannes Rieber und 11 weiteren Autor:innen. Beteiligte Einrichtung: Dept. of Cardiology, Medizinische Klinik-Innenstadt, University of Munich, Ziemssenstr. 1 80336 Munich, Germany. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Coronary Circulation, Stents. Die Arbeit wurde bisher 10-mal zitiert (Crossref).
Abstract (Originalsprache)
OBJECTIVES: Determination of fractional flow reserve (FFR) allows the functional assessment of coronary stenoses before and after an intervention. Preliminary data suggest that a FFR > or = 0.94 is associated with an excellent clinical outcome after stent implantation. However, these results were limited both by the number of patients included and the use of non-contemporary stent designs. We sought to determine the prognostic value of FFR measurements in a large patient cohort undergoing coronary stent implantation. METHODS: Eighty-nine consecutive patients were enrolled in whom a stent implantation was performed and a pressure wire was used as a guide wire. Patients were followed for at least 6 months. Death, myocardial infarction (MI) and target vessel revascularization (TVR) were considered cardiac events. A FFR > or = 0.94 was regarded as an optimal functional result. RESULTS: A complete follow-up was available in all patents. Pre-interventional FFR increased from 0.66 +/- 0.16 to 0.95 +/- 0.05 (p < 0.0001) after stent implantation. Sixteen (18%) events occurred during follow-up including 10 (11.2%) TVR. Final FFR was significantly higher in patients without compared to patients with an event (0.92 +/- 0.06 vs. 0.96 +/- 0.05, p < 0.003). By univariate analysis, the presence of diabetes mellitus, left ventricular function, residual diameter stenosis and final FFR were associated with a worse clinical outcome. In the multivariate analysis, only the final FFR and left ventricular function remained as significant predictors for cardiac events (relative risk, 3.50; 95% CI: 1.29-9.52, P < 0.014, and 0.97; 95% CI: 0.93-1.00, p = 0.047). CONCLUSION: These results demonstrate in a nonselected patient cohort a strong correlation between FFR values after coronary stenting and subsequent cardiac events. Further studies have to investigate whether outcome after stenting might be improved by guiding the procedure with a pressure guide wire.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Dept. of Cardiology, Medizinische Klinik-Innenstadt, University of Munich, Ziemssenstr. 1 80336 Munich, Germany.
Zitieren
APA
Rieber, J., Schiele, T. M., Erdin, P., Stempfle, H. U., König, A., Erhard, I., Segmiller, T., Baylacher, M., Theisen, K., Haufe, M. C., Siebert, U., & Klauss, V. (2002). Fractional flow reserve predicts major adverse cardiac events after coronary stent implantation. Zeitschrift f�r Kardiologie, 91(0), 132-136. https://doi.org/10.1007/s00392-002-1324-y
Vancouver
Rieber J, Schiele TM, Erdin P, Stempfle HU, König A, Erhard I, et al. Fractional flow reserve predicts major adverse cardiac events after coronary stent implantation. Zeitschrift f�r Kardiologie. 2002;91(0):132-136. doi:10.1007/s00392-002-1324-y
BibTeX
@article{Rieber2002,
author = {Rieber, Johannes and Schiele, Thomas M and Erdin, Petra and Stempfle, Hans-Ulrich and König, Andreas and Erhard, Isabelle and Segmiller, Tobias and Baylacher, Monika and Theisen, Karl and Haufe, Mathias C and Siebert, Uwe and Klauss, Volker},
title = {Fractional flow reserve predicts major adverse cardiac events after coronary stent implantation},
journal = {Zeitschrift f�r Kardiologie},
year = {2002},
volume = {91},
number = {0},
pages = {132--136},
doi = {10.1007/s00392-002-1324-y}
}
EUVIMED