EUVIMEDEUVIMED entdecken
LeitlinieOpen Access · CC BY 4.0

Utility guideline and considerations for the novel Hugo™ RAS (robotic-assisted surgery) system in colorectal surgery: surgical outcomes and initial experience in a tertiary center

Antonio Arroyo, Ana Sánchez-Romero, Álvaro Soler-Silva, Saray Quinto, Francisco López-Rodríguez-Arias, María-José Alcaide, Mónica Serrano-Navidad, Elena Miranda, José-Luis Muñoz, Luis Sánchez-Guillén

International Journal of Colorectal Disease · 18.09.2024 · 39 (1)

DOI: 10.1007/s00384-024-04715-7 ↗

Kurz gefasst

Leitlinie in der Zeitschrift International Journal of Colorectal Disease, online erschienen am 18.09.2024. Verfasst von Antonio Arroyo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Colorectal Unit, Department of General Surgery, Elche University Hospital, Elche (Alicante), Spain. aarroyo@umh.es. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Tertiary Care Centers. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Miguel Hernández.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A novel robotic platform—Hugo™ RAS (robotic-assisted surgery) system—has been introduced with several innovations that may prove advantageous for surgeons, such as an open console and four interchangeable modular arms. Our study aims to evaluate this platform’s safety, efficacy, and potential impact on the surgical treatment of colorectal pathology.

Methods

Patients underwent robotic-assisted colorectal procedures with the Hugo™ RAS system at the General University Hospital of Elche from October 2023 to July 2024. Patient characteristics, intraoperative and postoperative variables, and robotic technical issues were recorded.

Results

Forty consecutive patients were included (14 right, 13 left, and 8 rectum neoplasms; 4 left diverticulitis; and 1 ileocecal Crohn’s disease). The patients’ characteristics were as follows: median age, 69.5 years; 24 males and 16 females; 45% ASA III–IV; and Charlson Comorbidity Index > 5:42.5%. We recorded four medical (2 anemia, 1 phlebitis, and 1 admission to the intensive care unit) and three surgical (1 hematoma of the incision, 1 intestinal occlusion, and 1 dehiscence of the anastomosis) postoperative complications. We had no conversions neither open nor laparoscopic surgery. The average hospital stay was 3 days, with no mortality or readmission.

Conclusions

The Hugo™ RAS system is safe and feasible for colorectal procedures. The modularity of the arms provides the versatility of configurations adjusted depending on the patient’s body features and the surgeon’s preferences and greater adaptability to operating rooms. The open console is highly comfortable and ergonomic for the surgeon, allowing communication with the operating room environment.

Trial registration

NCT06512480

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresTertiary Care CentersHumansFemaleMaleAgedTreatment OutcomeMiddle AgedColorectal SurgeryPostoperative ComplicationsAged, 80 and overLength of StayAdult

Stichwörter der Autor:innen

Colorectal surgeryErgonomicsHugo™ RAS systemRobotic surgerySurgical innovations

Autor:innen und Institutionen

  • Colorectal Unit, Department of General Surgery, Elche University Hospital, Elche (Alicante), Spain. aarroyo@umh.es.
  • Department of Pathology and Surgery, Miguel Hernández University, San Juan de Alicante (Alicante), Spain. aarroyo@umh.es.
  • Colorectal Unit, Department of General Surgery, Elche University Hospital, Elche (Alicante), Spain.
  • Department of Pathology and Surgery, Miguel Hernández University, San Juan de Alicante (Alicante), Spain.
  • Department of Anesthesiology, Elche University Hospital, Elche (Alicante), Spain.

Förderung

  • Universidad Miguel Hernández

Zitieren

APA

Arroyo, A., Sánchez-Romero, A., Soler-Silva, Á., Quinto, S., López-Rodríguez-Arias, F., Alcaide, M. J., Serrano-Navidad, M., Miranda, E., Muñoz, J. L., & Sánchez-Guillén, L. (2024). Utility guideline and considerations for the novel Hugo™ RAS (robotic-assisted surgery) system in colorectal surgery: surgical outcomes and initial experience in a tertiary center. International Journal of Colorectal Disease, 39(1). https://doi.org/10.1007/s00384-024-04715-7

Vancouver

Arroyo A, Sánchez-Romero A, Soler-Silva Á, Quinto S, López-Rodríguez-Arias F, Alcaide MJ, et al. Utility guideline and considerations for the novel Hugo™ RAS (robotic-assisted surgery) system in colorectal surgery: surgical outcomes and initial experience in a tertiary center. International Journal of Colorectal Disease. 2024;39(1). doi:10.1007/s00384-024-04715-7

BibTeX
@article{Arroyo2024,
  author = {Arroyo, Antonio and Sánchez-Romero, Ana and Soler-Silva, Álvaro and Quinto, Saray and López-Rodríguez-Arias, Francisco and Alcaide, María-José and Serrano-Navidad, Mónica and Miranda, Elena and Muñoz, José-Luis and Sánchez-Guillén, Luis},
  title = {Utility guideline and considerations for the novel Hugo™ RAS (robotic-assisted surgery) system in colorectal surgery: surgical outcomes and initial experience in a tertiary center},
  journal = {International Journal of Colorectal Disease},
  year = {2024},
  volume = {39},
  number = {1},
  doi = {10.1007/s00384-024-04715-7}
}
Kostenlos starten →