The incremental yield of adenoma detection with I-Scan versus high-definition white light colonoscopy—a systematic review and meta-analysis of randomized studies

Maryam R Hussain, Faisal S Ali, Apoorva Tangri, Shahrooz Rashtak, Mairin Joseph-Talreja, Pritesh R Mutha, Vaibhav Wadhwa, Sushovan Guha, Roy Tomas DaVee, Nirav Thosani

International Journal of Colorectal Disease · 2023

DOI: 10.1007/s00384-023-04533-3 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift International Journal of Colorectal Disease, 2023. Verfasst von Maryam R Hussain und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Population Health and Health Disparities/School of Public and Population Health, University of Texas Medical Branch, Galveston, TX, USA. Hauptthemen laut MEDLINE: Adenoma, Colorectal Neoplasms, Polyps. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The incremental yield of I-Scan virtual chromoendoscopy compared to high-definition white light endoscopy (HD-WLE) in detection of colorectal adenomas has not been thoroughly elucidated. METHODS: A systematic search from inception to April 2023 was conducted to identify randomized controlled trials (RCTs) comparing I-Scan to HD-WLE for detection of adenomas. A random effects model was used to compute risk difference (RD) with corresponding 95% confidence intervals in adenoma detection rate (ADR). Influence analysis was done to assess robustness of findings. The number needed to diagnose was computed. Heterogeneity was assessed using the I2 statistic and explored further by subgroup analyses defined a priori. Certainty in effect estimates was assessed using the GRADE approach. RESULTS: We identified four studies (I-Scan n = 730, HD-WLE n = 765). I-Scan increased adenoma detection by 9% (risk difference (RD), 0.09; 0.04, 0.14; I2 02%; certainty, low). Influence analysis revealed that the gain in yield remained statistically significant with exclusion of all but one study. The number needed to capture one additional adenomatous polyp with I-Scan use was 11.2. I-Scan 1 use was associated with a statistically significant gain in ADR, whereas no significant difference in ADR was noted with I-Scan use on subgroup analysis. DISCUSSION: In conclusion, I-Scan increases the yield of adenoma detection by 9% compared to HD-WLE, with low certainty in the estimate of this effect. Data on the gain in yield of detecting large polyps, sessile serrated lesions, and on the impact of formally training endoscopists and trainees in I-Scan use and similar technology on adenoma detection rate are needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdenomaColorectal NeoplasmsPolypsHumansColonoscopyLight

Stichwörter der Autor:innen

Adenoma detection rateAdenomatous polypsColon cancerGRADEI-ScanMeta-analysis

Autor:innen und Institutionen

  • Department of Population Health and Health Disparities/School of Public and Population Health, University of Texas Medical Branch, Galveston, TX, USA.
  • Department of Gastroenterology, Hepatology, and Nutrition, The University of Texas Health Science Center, Houston, TX, USA. faisal.s.ali@uth.tmc.edu.
  • Department of Internal Medicine, Woodhull Hospital, New York, NY, USA.
  • Center for Interventional Gastroenterology at UTHealth (iGUT), Department of Surgery, Division of Endoluminal Surgery and Interventional Gastroenterology, McGovern Medical School at UTHealth, Houston, TX, USA.
  • Center for Interventional Gastroenterology at UTHealth (iGUT), Department of Surgery, Division of Endoluminal Surgery and Interventional Gastroenterology, McGovern Medical School at UTHealth, Houston, TX, USA. Nirav.tho…

Zitieren

APA

Hussain, M. R., Ali, F. S., Tangri, A., Rashtak, S., Joseph-Talreja, M., Mutha, P. R., Wadhwa, V., Guha, S., DaVee, R. T., & Thosani, N. (2023). The incremental yield of adenoma detection with I-Scan versus high-definition white light colonoscopy—a systematic review and meta-analysis of randomized studies. International Journal of Colorectal Disease. https://doi.org/10.1007/s00384-023-04533-3

Vancouver

Hussain MR, Ali FS, Tangri A, Rashtak S, Joseph-Talreja M, Mutha PR, et al. The incremental yield of adenoma detection with I-Scan versus high-definition white light colonoscopy—a systematic review and meta-analysis of randomized studies. International Journal of Colorectal Disease. 2023. doi:10.1007/s00384-023-04533-3

BibTeX
@article{Hussain2023,
  author = {Hussain, Maryam R and Ali, Faisal S and Tangri, Apoorva and Rashtak, Shahrooz and Joseph-Talreja, Mairin and Mutha, Pritesh R and Wadhwa, Vaibhav and Guha, Sushovan and DaVee, Roy Tomas and Thosani, Nirav},
  title = {The incremental yield of adenoma detection with I-Scan versus high-definition white light colonoscopy—a systematic review and meta-analysis of randomized studies},
  journal = {International Journal of Colorectal Disease},
  year = {2023},
  doi = {10.1007/s00384-023-04533-3}
}
Kostenlos starten →