EUVIMEDEUVIMED entdecken
FallberichtÜbersichtsarbeitOpen Access · CC BY-NC-ND 4.0

Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature

Tomoko Tanaka, Eliezer Villanueva-Castro, Hector Soriano-Baron

Child's Nervous System · 2026

DOI: 10.1007/s00381-026-07157-4 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Child's Nervous System, 2026. Verfasst von Tomoko Tanaka und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA. ttanaka@uams.edu. Hauptthemen laut MEDLINE: Ketones, Polyethylene Glycols, Spinal Neoplasms, Spinal Fusion. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) spinal implants lessen MRI artifacts compared with titanium, potentially improving surveillance and radiotherapy planning; pediatric experience remains limited. We sought to demonstrate feasibility and imaging/radiotherapy workflow advantages in children with spinal tumors. CASE DESCRIPTIONS: An 11-year-old boy with retroclival chordoma underwent occipitocervical fusion (occiput-C5) using CFR-PEEK lateral mass screws with conventional occipital hardware; postoperative MRI sharply delineated the operative bed and enabled proton planning; he is disease-free at 6 months. A 15-year-old boy with recurrent L2-L3 Ewing sarcoma underwent laminectomy with facetectomy, gross-total resection, and L2-L3 fusion using CFR-PEEK pedicle screws; postoperative imaging showed minimal artifact and facilitated proton planning; he is disease-free at 11 months. DISCUSSION: Across both cases, radiolucency and markedly reduced artifact improved visualization of the tumor bed and thecal sac, supporting accurate target definition for proton therapy without compromising construct stability; pediatric constraints (e.g., lack of CFR-PEEK occipital components) were manageable with hybrid hardware. CONCLUSION: CFR-PEEK appears to be a practical and promising option for pediatric spinal oncology when long-term MRI surveillance and adjuvant radiotherapy are anticipated. Our experience, alongside a focused literature review, supports selective use and motivates prospective pediatric studies to confirm imaging, radiotherapy, and durability benefits.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KetonesPolyethylene GlycolsSpinal NeoplasmsSpinal FusionCarbonChordomaSarcoma, EwingHumansBenzophenonesMalePolymersChildAdolescentCarbon FiberPolyether CompoundsMagnetic Resonance Imaging

Stichwörter der Autor:innen

Artifact reductionCarbon fiber–reinforced polyetheretherketoneOccipitocervical fusionPediatric spinal oncologySpinal instrumentation

Substanzen

BenzophenonespolyetheretherketonePolymersKetonesPolyethylene GlycolsCarbon FiberPolyether CompoundsCarbon

Autor:innen und Institutionen

  • Department of Neurosurgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA. ttanaka@uams.edu.
  • Department of Neurosurgery, Arkansas Children's Research Institute, Little Rock, AR, USA. ttanaka@uams.edu.
  • Department of Neurosurgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA.

Zitieren

APA

Tanaka, T., Villanueva-Castro, E., & Soriano-Baron, H. (2026). Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature. Child's Nervous System. https://doi.org/10.1007/s00381-026-07157-4

Vancouver

Tanaka T, Villanueva-Castro E, Soriano-Baron H. Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature. Child's Nervous System. 2026. doi:10.1007/s00381-026-07157-4

BibTeX
@article{Tanaka2026,
  author = {Tanaka, Tomoko and Villanueva-Castro, Eliezer and Soriano-Baron, Hector},
  title = {Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature},
  journal = {Child's Nervous System},
  year = {2026},
  doi = {10.1007/s00381-026-07157-4}
}
Kostenlos starten →