Reducing radiation exposure in pediatric cervical spine imaging for trauma: a multi-disciplinary quality improvement initiative
Child's Nervous System · 2025-12 · 41 (1)
DOI: 10.1007/s00381-025-06754-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Child's Nervous System, online erschienen am 03.02.2025. Verfasst von Nina Yu und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of California, Davis, School of Medicine, Sacramento, CA, 95817, USA. Hauptthemen laut MEDLINE: Cervical Vertebrae, Tomography, X-Ray Computed, Quality Improvement, Radiation Exposure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Pediatric cervical spine injury (PCSI) can result in devastating neurologic disability. While computed tomography (CT) imaging is both sensitive and specific in detecting clinically significant injuries, indiscriminate utilization can lead to excessive ionizing radiation exposure. A routine institutional audit revealed CTs were inappropriately obtained 54% of the time. This study evaluates the effects of an updated protocol to reduce radiation exposure in pediatric trauma patients.
Methods
Data were retrospectively analyzed from a pediatric level 1 trauma center from 2021 to 2022. The data were divided into two cohorts, pre-implementation (2021) and post-implementation (2022). Inclusion criteria were patients 0–14 years old with a Glasgow Coma Scale (GCS) ranging 9–15. Outside-hospital transfers were excluded. The primary study endpoints were guideline compliance and CT utilization.
Results
A total of 82 subjects were enrolled in this study. In 2021, there were 38 subjects (female/male 15/23, mean age 5.9 years old) with an average GCS of 13.6. In 2022, there were 44 subjects (female/male 19/25, mean age 5.2 years old) with an average GCS of 14.0. In 2021, the overall protocol adherence rate was 81.6%, and post-implementation in 2022, compliance was 93.2% ( p = 0.109). Following implementation, the rate of inappropriate (protocol non-adherent CT) use decreased from 58.6 to 6.8% ( p < 0.05).
Conclusions
Implementation of a new evidence-based institutional protocol for PCSI was associated with improved adherence and reduction of unnecessary CT orders. Ongoing monitoring will help determine if these improvements are sustained.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of California, Davis, School of Medicine, Sacramento, CA, 95817, USA.
- Department of Surgery, University of California, Davis, Sacramento, CA, 95817, USA.
- Department of Emergency Medicine, University of California, Davis, Sacramento, CA, 95817, USA.
- Department of Neurological Surgery, University of California, Davis, 4860 Y St., Suite 3740, Sacramento, CA, 95817, USA. mzwien@ucdavis.edu.
Zitieren
APA
Yu, N., Kohler, J. E., Grether-Jones, K., Murphy, M., & Zwienenberg, M. (2025). Reducing radiation exposure in pediatric cervical spine imaging for trauma: a multi-disciplinary quality improvement initiative. Child's Nervous System, 41(1). https://doi.org/10.1007/s00381-025-06754-z
Vancouver
Yu N, Kohler JE, Grether-Jones K, Murphy M, Zwienenberg M. Reducing radiation exposure in pediatric cervical spine imaging for trauma: a multi-disciplinary quality improvement initiative. Child's Nervous System. 2025;41(1). doi:10.1007/s00381-025-06754-z
BibTeX
@article{Yu2025,
author = {Yu, Nina and Kohler, Jonathan Emerson and Grether-Jones, Kendra and Murphy, Maureen and Zwienenberg, Marike},
title = {Reducing radiation exposure in pediatric cervical spine imaging for trauma: a multi-disciplinary quality improvement initiative},
journal = {Child's Nervous System},
year = {2025},
volume = {41},
number = {1},
doi = {10.1007/s00381-025-06754-z}
}
EUVIMED