EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of failure rates between full-barium and striped barium distal shunt catheters: a matched case–control study

Sage P Rahm, Nicholas M B Laskay, Samuel G McClugage, Joshua D Jackson, Anastasia Arynchyna-Smith, Curtis J Rozzelle, Brandon G Rocque

Child's Nervous System · 2025

DOI: 10.1007/s00381-024-06747-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Child's Nervous System, 2025. Verfasst von Sage P Rahm und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Division of Pediatric Neurosurgery, University of Alabama at Birmingham, Children's of Alabama, 1600 7th Avenue South, Lo…. Hauptthemen laut MEDLINE: Equipment Failure, Hydrocephalus, Cerebrospinal Fluid Shunts, Barium. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We hypothesize that distal shunt catheters fully impregnated with barium are more prone to failure compared to distal catheters with only a barium stripe. We sought to evaluate this distinction using a matched case–control study.

Methods

Patient records over an 8-year period were queried for distal shunt revisions for fracture or disconnection (cases). A control group of patients with confirmed functioning distal catheters was queried from the same period and matched based on patient age at exploration/revision. Data were collected via chart review, including demographics, hydrocephalus etiology, distal catheter type, and patient age at revision. Independent T -test, chi-squared, and binomial logistic regression analyses were performed.

Results

There were 194 patients included in the study: 97 patients with distal shunt revision and 97 controls with a functional distal shunt system. The mean patient age at distal catheter revision was 12.87 ± 4.59 years, and the mean patient age of the control group was 12.81 ± 4.59 years. The most common etiology was premature intraventricular hemorrhage (32%). Of the distal failures, 41.2% had fully impregnated barium catheters, while 58.8% had striped barium catheters. Of the control group, 76/97 (78%) patients had barium-striped distal shunt catheters and 21/97 (22%) had fully impregnated catheters. Logistic regression analysis showed that fully impregnated catheters were more likely than striped barium to fail, p = 0.004 (OR = 2.54, 95% CI 1.35–4.77).

Conclusion

In a matched case–control format, odds of failure of fully impregnated distal catheters were 2.54 greater than striped barium catheters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Equipment FailureHydrocephalusCerebrospinal Fluid ShuntsBariumCathetersHumansCase-Control StudiesMaleFemaleChildAdolescentChild, PreschoolRetrospective StudiesReoperationInfant

Stichwörter der Autor:innen

Barium cathetersDistal shunt failureStriped cathetersVentriculoperitoneal shunt

Substanzen

Barium

Autor:innen und Institutionen

  • Department of Neurosurgery, Division of Pediatric Neurosurgery, University of Alabama at Birmingham, Children's of Alabama, 1600 7th Avenue South, Lowder 400, Birmingham, AL, 35233, USA. sprahm@uabmc.edu.
  • Department of Neurosurgery, Division of Pediatric Neurosurgery, University of Alabama at Birmingham, Children's of Alabama, 1600 7th Avenue South, Lowder 400, Birmingham, AL, 35233, USA.
  • Department of Neurosurgery, Texas Children's Hospital, Houston, TX, USA.
  • Department of Neurosurgery, Duke University School of Medicine, Durham, NC, USA.

Zitieren

APA

Rahm, S. P., Laskay, N. M. B., McClugage, S. G., Jackson, J. D., Arynchyna-Smith, A., Rozzelle, C. J., & Rocque, B. G. (2025). Comparison of failure rates between full-barium and striped barium distal shunt catheters: a matched case–control study. Child's Nervous System. https://doi.org/10.1007/s00381-024-06747-4

Vancouver

Rahm SP, Laskay NMB, McClugage SG, Jackson JD, Arynchyna-Smith A, Rozzelle CJ, et al. Comparison of failure rates between full-barium and striped barium distal shunt catheters: a matched case–control study. Child's Nervous System. 2025. doi:10.1007/s00381-024-06747-4

BibTeX
@article{Rahm2025,
  author = {Rahm, Sage P and Laskay, Nicholas M B and McClugage, Samuel G and Jackson, Joshua D and Arynchyna-Smith, Anastasia and Rozzelle, Curtis J and Rocque, Brandon G},
  title = {Comparison of failure rates between full-barium and striped barium distal shunt catheters: a matched case–control study},
  journal = {Child's Nervous System},
  year = {2025},
  doi = {10.1007/s00381-024-06747-4}
}
Kostenlos starten →