Methodology for pediatric head computed tomography image segmentation and volumetric calculation using a tablet computer and stylus pen
Child's Nervous System · 2025
DOI: 10.1007/s00381-024-06723-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Child's Nervous System, 2025. Verfasst von H Hashimoto und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Osaka Women's and Children's Hospital, Izumi, Osaka, 594-1101, Japan. h-hashimoto@ndr.med.osaka-u.ac.jp. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Osaka University.
Abstract (Originalsprache)
Purpose
This study presents a MATrix LABoratory (MATLAB)-based methodology for calculating intracranial volumes from head computed tomography (CT) data and compares it with established methods.
Methods
Regions of interest (ROI) were manually segmented on CT images using a stylus pen, facilitated by mirroring a computer desktop onto a tablet. The volumetric process involved three main steps: (1) calculating the volume of a single voxel, (2) counting the total number of voxels within the segmented ROI, and (3) multiplying this voxel count by the single-voxel volume. This method was applied to 83 pediatric head CT scans from patients with minor head trauma, and the volumetric results were compared with those obtained from OsiriX.
Results
A paired t-test revealed a statistically significant difference ( p < 0.001) between volumes obtained with our MATLAB-based method and those from OsiriX, with our method measuring 0.32% higher. However, an unpaired t-test found no statistically significant differences between the volumetric population groups ( p = 0.84).
Conclusion
The significant difference identified by the paired t-test likely reflects statistical distinctions arising from differences in the calculation methods of the two approaches. Conversely, the unpaired t-test suggests no statistically detectable differences between the volumetric populations. Although this does not imply that the two methods produce identical results, the volumetric populations derived from our method may originate from the same underlying population as those obtained using OsiriX. By taking these points into account, our method has the potential to serve as a valuable tool for volumetric measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Osaka Women's and Children's Hospital, Izumi, Osaka, 594-1101, Japan. h-hashimoto@ndr.med.osaka-u.ac.jp.
- Department of Neurological Diagnosis and Restoration, Graduate School of Medicine, Osaka University, Suita, Osaka, 565-0871, Japan. h-hashimoto@ndr.med.osaka-u.ac.jp.
- Center for Neurotechnology and Neurorecovery, Department of Neurology, Massachusetts General Hospital, Boston, MA, 02114, USA. h-hashimoto@ndr.med.osaka-u.ac.jp.
- Department of Neurology, Harvard Medical School, Boston, MA, 02115, USA. h-hashimoto@ndr.med.osaka-u.ac.jp.
- Department of Radiology, Osaka Women's and Children's Hospital, Izumi, Osaka, 594-1101, Japan.
- Department of Neurosurgery, Osaka Women's and Children's Hospital, Izumi, Osaka, 594-1101, Japan.
ORCID-Profile: H Hashimoto
Förderung
- Japan Society for the Promotion of Science
- Osaka University
Zitieren
APA
Hashimoto, H., Shimada, M., Takemoto, O., & Chiba, Y. (2025). Methodology for pediatric head computed tomography image segmentation and volumetric calculation using a tablet computer and stylus pen. Child's Nervous System. https://doi.org/10.1007/s00381-024-06723-y
Vancouver
Hashimoto H, Shimada M, Takemoto O, Chiba Y. Methodology for pediatric head computed tomography image segmentation and volumetric calculation using a tablet computer and stylus pen. Child's Nervous System. 2025. doi:10.1007/s00381-024-06723-y
BibTeX
@article{Hashimoto2025,
author = {Hashimoto, H and Shimada, M and Takemoto, O and Chiba, Y},
title = {Methodology for pediatric head computed tomography image segmentation and volumetric calculation using a tablet computer and stylus pen},
journal = {Child's Nervous System},
year = {2025},
doi = {10.1007/s00381-024-06723-y}
}